![ORGA L85EX Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/orga/l85ex/l85ex_installation-and-maintenance-manual_1650420025.webp)
Version 2.1
25
MAINTENANCE
3
MAINTENANCE
3.1
Advised maintenance schedule
3.2
Maintenance procedures
3.2.1
Clean the dome(s)
1.
Clean the dome(s).
Use a damp cloth or fresh water and a mild cleaning detergent to
prevent potential electrostatic charging hazards
.
WARNING
Only an electrical engineer is allowed to do maintenance on the electrical
system.
System unit
Task
Limit
Step
Domes
Visual inspection on con-
tamination
Every 12 months
Clean. Refer to
Visual inspection on
scratches and other dam-
age
Every 12 months
Contact Orga.
Base
Visual inspection of the
coating on damage and
corrosion
Every 12 months
Contact Orga.
External earth
connection
Visual inspection on cor-
rect fastening
Every 12 months
Correct the fastening.
Refer to
Fixing bolts and
nuts of the entire
lantern
Visual inspection on cor-
rect fastening
Every 12 months
Correct the fastening.
Refer to
Lighting fixture
Inspect the electrical con-
nections
Every 12 months
Refer to
.
Central control
panel
Failure of the lantern could
result in an alarm message
at the central control panel.
In case of alarm mes-
sages, see the instruc-
tions of the central control
panel.
CAUTION
For cleaning:
•
Always use a damp cloth or fresh water to prevent potential electrostatic
charging hazards.
•
Never use solvents of any kind.
Содержание L85EX
Страница 14: ...DESCRIPTION 14 Version 2 1...
Страница 22: ...INSTALLATION 22 Version 2 1...
Страница 26: ...MAINTENANCE 26 Version 2 1...
Страница 30: ...TROUBLESHOOTING 30 Version 2 1...
Страница 59: ...Version 2 1 59 C IECEx CERTIFICATE C 1 IECEx Certificate of Conformity L85EX...
Страница 60: ...60 Version 2 1...
Страница 61: ...Version 2 1 61...
Страница 62: ...62 Version 2 1...
Страница 63: ...Version 2 1 63...
Страница 64: ...64 Version 2 1...
Страница 66: ...66 Version 2 1...