Oregon Scientific THN132ES Скачать руководство пользователя страница 3

中文繁

EN

Remote Sensor with solar panel 

Model: Thermo THN132ES /
Thermo-Hygro THGN132ES

USER MANUAL

OVERVIEW

FRONT VIEW

 

1

2

1.  Solar panel
2.  LED status indicator: blinks when transmitting a reading

BACK VIEW

1

2

3

5

4

RESET

TEST

1

2

3

CHANNEL

1.  Wall mount hole
2. 

RESET

:

 

Reset unit to default settings

3. 

TEST

: determines if solar panel is receiving an optimal 

amount of sunlight

4.  Battery compartment
5. 

CHANNEL

 switch

GETTING STARTED

SENSOR SET UP

This product uses 1 AAA rechargeable battery which should 
be charged via the solar panel. 

  IMPORTANT   

Place

  ONLY 

NiMH  type  rechargeable 

batteries  in  the  solar  panel  battery  compartment.  Do  not 
charge non-rechargeable batteries.

 NOTE 

 Install battery in the remote sensor before the main 

unit.

To set up the remote sensor:

1.  Slide open the battery door.
2.  Slide channel switch to select a channel (1, 2, 3).  Ensure 

you use a different channel for each sensor.

3.  Insert the battery, matching the polarities (+/-).
4.  Press

 RESET

 after each battery change.

 TIP 

 To keep battery in best condition, it is strongly advised 

to charge it for at least 12 hours before first use.
5.  Initiate a sensor search on the main unit to start receiving 

temperature  (and  humidity  -  THGN132ES  only)  data 
from the sensor.

IDEAL LOCATIONS FOR REMOTE SENSOR

The  sensor’s  solar  panel  does  not  require  direct  sunlight.  
The ambient or reflective light of the sun will provide enough 
light to effectively charge the batteries.

Ideal placements for the sensor would be in any location on 
the exterior of the home at a height of not more than 1.5m 
(5  ft)  and  which  can  shield  it  from  direct  sunlight  or  wet 
conditions for an accurate reading.

1.5 m (5 ft)

To  check  if  there  is  sufficient  sunlight  at  selected 
location:

Press 

TEST

 located in the battery compartment.

Green  LED  (directly  above  TEST)  will  light  up  to  indicate 
battery is being charged.

For best results:

• 

Place the sensor within 30 m (100 ft) of the main unit.

• 

Place the sensor out of direct sunlight and moisture.

• 

Position  the  sensor  so  that  it  faces  the  main  (indoor) 
unit,  minimizing  obstructions  such  as  doors,  walls  and 
furniture.

• 

Place the sensor in a location with a clear view to the 
sky, away from metallic / electronic objects.

• 

Position  the  sensor  close  to  the  main  unit  during  cold 
winter  months  as  below-freezing  temperatures  may 
affect battery performance and signal transmission.

 TIP 

 The transmission range may vary depending on many 

factors. You may need to experiment with various locations 
to get the best results.

Solar panel:

• 

Direct solar panel as follows:

Solar panel facing:

If you reside in the:

North

Southern hemisphere

South

Northern hemisphere

• 

Do not scratch the solar panel’s surface or wipe it with 
strong detergent.

• 

Do  not  expose  the  solar  panel  to  rain,  snow  or 
moisture.

• 

The duration of the rechargeable battery’s charging or 
operating  time  is  determined  by  either  the  intensity  of 
sunlight  or  the  position  of  the  solar  panel  towards  the 
sun.

• 

Do not overcharge the batteries.

Securing the sensor:

• 

Secure the sensor in the desired location.

Each 4 hour charge in optimal conditions generates enough 
power to operate the unit for 1 week when weather conditions 
are not ideal.

CHANGING CHANNELS

To  change  channels  once  channel  has  been 
assigned:

1.  Slide channel switch to desired channel.
2.  Press 

RESET

.

3.  Initiate a sensor search on the main unit to start receiving 

temperature  (and  humidity  –  THGN132ES  only)  data 
from the sensor.

RESET

Press 

RESET

 to return to the default settings.

TROUBLE SHOOTING

PROBLEM

SYMPTOM

REMEDY

Remote 
sensor

Abnormal / 
strange readings

Press 

RESET

Cannot locate 
remote sensor

Check battery
Check location

Cannot change 
channel

Check sensors. Only 
one sensor is working

Data does not 
match main unit

Initiate a manual 
sensor search

PRECAUTIONS

• 

Do not subject the unit to excessive force, shock, dust, 
temperature or humidity.

• 

Do not cover the ventilation holes with any items such as 
newspapers, curtains etc.

• 

Do not immerse the unit in water. If you spill liquid over 
it, dry it immediately with a soft, lint-free cloth.

• 

Do  not  clean  the  unit  with  abrasive  or  corrosive 
materials. 

• 

Do not tamper with the unit’s internal components. This 
invalidates the warranty.

• 

Only  use  fresh  batteries.  Do  not  mix  new  and  old 
batteries.

• 

Images shown in this manual may differ from the actual 
display.

• 

When  disposing  of  this  product,  ensure  it  is  collected 
separately  for  special  treatment  and  not  as  household 
waste.

• 

Placement  of  this  product  on  certain  types  of  wood 
may  result  in  damage  to  its  finish  for  which  Oregon 
Scientific  will  not  be  responsible.  Consult  the  furniture 
manufacturer's care instructions for information.

• 

The  contents  of  this  manual  may  not  be  reproduced 
without the permission of the manufacturer.

• 

Do  not  dispose  old  batteries  as  unsorted  municipal 
waste.  Collection  of  such  waste  separately  for  special 
treatment is necessary.

• 

Please  note  that  some  units  are  equipped  with  a 
battery  safety  strip.  Remove  the  strip  from  the  battery 
compartment before first use.

 NOTE 

 The technical specifications for this product and the 

contents of the user manual are subject to change without 
notice.

 NOTE 

 Features and accessories will not be available in all 

countries.  For  more  information,  please  contact  your  local 
retailer.

SPECIFICATIONS

TYPE

DESCRIPTION

L x W x H

60 x 105 x 22 mm 
(2.36 x 4.13 x 0.86 in)

Weight

241 g (8.5 oz) without battery

Temperature range

-20°C to 60°C (-4°F to 140°F)

Humidity range

25% - 95% (THGN132ES only)

Signal frequency 

433 MHz

Transmission range

30 m (100 ft) unobstructed

No. of channels

3

Power

1 x UM-4 (AAA) 1.2 V 
rechargeable battery

 NOTE 

• 

Model THN132ES is an outdoor temperature sensor.

• 

Model  THGN132ES  is  an  outdoor  temperature  and 
humidity sensor.

ABOUT OREGON SCIENTIFIC

Visit our website (www.oregonscientific.com) to learn more 
about Oregon Scientific products. 
If you're in the US and would like to contact our Customer 
Care department directly, please visit: www2.oregonscientific.
com/service/support.asp
For international inquiries, please visit: 
www2.oregonscientific.com/about/international.asp

遙控感應器附太陽能板 

機型︰Thermo THN132ES /

Thermo-Hygro THGN132ES

使用說明書

概要

正面圖

 

1

2

1.  太陽能板
2.  LED狀態指示器︰傳送數據時將閃爍

背面圖

1

2

3

5

4

RESET

TEST

1

2

3

CHANNEL

1.  牆壁固定孔
2. 

重設

︰將機體重設為預設設定

3. 

測試

︰決定太陽能板是否正在接收最佳陽光量

4.  電池格
5. 

頻道

切換

開始操作

感應器設定

本產品使用一枚應透過太陽能板充電的AAA可充電電池。

  重要 

  太陽能電池板電池格內只可裝入鎳氫型充電電池。切

勿將非充電電池充電。

 註 

 先安裝感應器內的電池,再安裝主機體的電池。

設置遙距感應器:

1.  滑開電池門。
2.  滑動頻道開關以選擇頻道(1, 2, 3)。應確保各感應器使用

不同的頻道。

3.  按極性方向裝入電池(+/-)。
4.  每次更換電池後按

重設

  秘訣 

  為保持電池的最佳狀態,強烈建議閣下首次使用前先

充電最少12小時。

5.  啟動主機體的感應器搜尋,開始接收來自感應器的溫度

(及濕度-僅THGN132ES提供)數據。

遙控感應器理想的放置位置

感應器的太陽能板無須陽光直接照射。陽光照射的環境或陽
光反射,將提供充足的陽光,以有效為電池充電。

感應器的理想擺放位置為房屋外牆上的任何地方,唯高度
不超過1.5米(5英尺)、並位於能遮擋直射陽光和雨水的地
方,以獲得精確的讀數。

1.5 m (5 ft)

欲檢查特定地點的陽光是否充足︰

按位於電池格的

測試

綠色的LED(就位於

測試

的上方)將亮起,說明正在為電池充

電。

欲取得最佳效果:

• 

將感應器放在與主機體距離在 30 米(100 呎) 內的位置。

• 

把感應器放在遠離陽光直射和潮濕的地方。

P/N:300102618-00003-10 REV1

1/2

Содержание THN132ES

Страница 1: ...HIARAZIONE DI CONFORMITÁ UE Con la presente Oregon Scientific dichiara che questo prodotto modello THN132ES THGN132ES è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999 5 CE Una copia firmata e datata della Dichiarazione di Conformità è disponibile su richiesta tramite il servizio clienti della Oregon Scientific PAESI CONFORMI ALLA DIRETTIVA R TTE ...

Страница 2: ...overige relevante bepalingen van Richtlijn 1999 5 EC Een kopie van de getekende en gedateerde Conformiteits verklaring is op verzoek beschikbaar via onze Oregon Scientific klanten service LANDEN DIE ZIJN ONDERWORPEN AAN RTT E Alle EU landen Zwitserland CH en Noorwegen N Sensor Remoto com Painel Solar Modelo Termo THN132ES Termo Higro THGN132ES MANUAL DO USUÁRIO VISÃO GERAL VISTA FRONTAL 1 2 1 Paine...

Страница 3: ...Press RESET 3 Initiate a sensor search on the main unit to start receiving temperature and humidity THGN132ES only data from the sensor RESET Press RESET to return to the default settings TROUBLE SHOOTING PROBLEM SYMPTOM REMEDY Remote sensor Abnormal strange readings Press RESET Cannot locate remote sensor Check battery Check location Cannot change channel Check sensors Only one sensor is working ...

Страница 4: ... 池 切勿對非充電電池充電 注 遠端傳感器內的電池應先於主機安裝 設置遠端傳感器 1 滑開電池倉門 2 滑動頻道開關 選擇某一頻道 1 2 3 應確保各傳感 器使用不同的頻道 3 按極性方向裝入電池 4 每次更換電池後按重置 提示 為使電池保持在最佳狀態 強烈建議您首次使用前至 少應充電12小時 5 在主機上啟動傳感器搜索 開始從傳感器接收溫度 及濕 度 僅限THGN132ES 資料 遠端傳感器的理想設置位置 傳感器的太陽能電池板不需要直射陽光 環境或反射陽光即 可為電池有效充電提供足夠的光線 為獲得精確的讀數 應將傳感器安放在房屋外牆上高度不超 過1 5米 5英尺 可遮擋直射陽光和防止受潮的位置 1 5 m 5 ft 檢查所選位置的陽光是否充足 按位於電池倉內的測試 綠色LED 位於測試的正上方 將點亮 表示正在為電池充 電 為獲得最佳效果 傳感器應設置在距主機 30 米 100 英尺 ...

Отзывы: