background image

5

GETTING STARTED

Once batteries are placed in a given remote sensor unit, it will start
transmitting information at 40-second intervals.

Also, for approximately a 3-minute duration, the main unit will
automatically search for signals once batteries are installed. Upon
successful reception, the individual channel temperature reading
will be displayed on the top line and the respective humidity reading
on the bottom line. The main unit will automatically update its
readings at about 40-second intervals.

If no signals are received, blanks “ --- ” will be displayed and the
kinetic wave icon will not show.

To force a signal search:

 • Press and hold IN/REMOTE  for 2-seconds to enforce a

3-minute search.

This is useful in synchronizing the transmission and reception of the
remote and main units.

Repeat this step whenever you find discrepancies between the
reading shown on the main unit and that on the respective remote
unit.

HOW TO CHECK REMOTE AND

INDOORS TEMPERATURES

Display of readings from a remote sensor or the main unit is a one-
step procedure. The remote sensor channel or the main unit display
is indicated in a box under the kinetic-wave icon.

Kinetic-wave

Icon

Designated

Indoor

Remote

Remote

Remote

Display

Display

Display

Display

Display

Channel One Channel Two Channel Three

To display temperature / humidity readings from the main unit:

 • Press IN / REMOTE until a dot is displayed in the box under the

kinetic-wave.

To display temperature / humidity readings from a remote
sensor:

 • Press CHANNEL until the appropriate remote sensor channel is

displayed in the box under the kinetic-wave.

If no readings are received form one particular channel for more than
15 minutes, blanks “ --- ” will be displayed until further readings are
successfully searched. Check the remote sensor to ensure that it is
secure and that the correct channel has been selected. Optionally,
press and hold IN/REMOTE for 2-seconds to enforce a search.

HOW TO READ

THE KINETIC-WAVE DISPLAY

The kinetic-wave display shows the signal-receiving status of the
main unit. There are three possible forms:

Содержание EMR963HG

Страница 1: ...outdoor temperatures humidity maximum and minimum recordings and trend indicators The unit supports up to three 433MHz remote thermo sensors or thermo hygro sensors A variety of additional sensors can...

Страница 2: ...e upper or lower temperature and humidity of individual channels G AL ON OFF button Activates or deactivates alarm H RESET Returns all settings to default values and erases all memories I C F slide sw...

Страница 3: ...t to the remote unit reset the main unit after installing batteries This will ensure easier synchronization between the transmission and reception of signals 4 Positiontheremoteunitandmainunitwithinef...

Страница 4: ...Note that once a channel is assigned to a remote unit you can only change it by removing the batteries or resetting the unit BATTERY INSTALLATION MAIN UNIT The main unit uses two 2 UM 3 or AA size alk...

Страница 5: ...CHECK REMOTE AND INDOORS TEMPERATURES Display of readings from a remote sensor or the main unit is a one step procedure The remote sensor channel or the main unit display is indicated in a box under t...

Страница 6: ...the temperature goes above or below the temperature measuring range of the main unit or the remote unit stated in specification the display will show HHH or LLL REMOTE SENSOR SCANNING The unit can be...

Страница 7: ...are recorded HOW TO USE CHANNEL 1 TEMPERATURE HUMIDITY ALARM Upper and lower temperature and humidity limits for channel 1 can be set so that an alarm activates when the limits are exceeded The high...

Страница 8: ...a 1 minute Press any key to momentarily stop the alarm The alarm will activate again if the limit continues exceeds the set limit Note If a second limit is passed while an alarm is active the first a...

Страница 9: ...switch of the main unit Whatever the display units of the remote sensors are they will be automatically converted to the chosen one of the main unit LOW BATTERY WARNING When it is time to replace bat...

Страница 10: ...lcomponents Doingsowill invalidate the warranty on the unit and may cause unnecessary damage The unit contains no user serviceable parts 5 Only use fresh batteries as specified in the user s manual Do...

Страница 11: ...with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation...

Страница 12: ...f the manufacturer WARRANTY This product is warranted to be free of defects in manufacturing for 90 days after purchase For technical support please call 800 853 8883 Monday Friday 8am 5pm PST Defecti...

Отзывы: