background image

 

It is important to relax when taking your blood 

pressure. Try to take a 15-minute rest before 

you begin. 

 

Do not lean backward or bend your wrist 

inward while taking a measurement. 

 

Do not sit cross-legged and avoid talking or 

moving your fingers and hand while taking a 

measurement. Rapid movements or other 

activities may alter your reading. 

 

Wait at least an hour before taking your blood 

pressure if you have just eaten a large meal. 

 

Do not smoke or drink alcohol before taking 

your blood pressure. 

 

Do not measure your blood pressure if you 

are under stress. 

 

Remove all accessories from your arm. 

 

Wait at least 3 minutes between 

measurements. This allows your blood 

circulation to recover. 

For a meaningful comparison, try to measure 

under similar conditions. For example, take daily 

measurements at approximately the same time, 

on the same arm, or as directed by a physician. 

 

 

TAKING A MEASUREMENT 

If you want the monitor to synchronize with the 

application of your mobile device. Please do 

preparation before starting a measurement. 

1.  Relax your arm. 

2.  Press 

  to turn on the unit.   

3.  Select user, then a voice prompts you to sit 

in the correct position and to remain still : 

Button 

User 

Memory 

 

Guest 

No records stored 

 

Record stored under User 1 

 

Record stored under User 2 

4.  Arm cuff will begin inflating automatically. 

Digits will appear on the screen.   

5.  Once the pressure reaches a certain level, it 

will slowly deflate until the results are 

displayed on the LCD.   

 

NOTE

 To stop the measurement process at 

any time, press

6.  The monitor automatically attempts to send 

the record wirelessly to your mobile device.   

If data transmission fails, 

Err 1

 will appear 

while a voice prompts. 

7.  To conserve battery life, monitor will turn off 

1 minute after taking a measurement.   

Alternatively, press 

  to manually turn off 

monitor. 

 

UNDERSTANDING THE READING 

For reference material, please refer to 

Useful 

Reference

 section which can be found at the end 

of this manual. 

 

DISPLAY 

Current reading & Average morning / evening 

reading 

If there is an average reading, the screen display 

will toggle between current reading and average 

morning or evening reading (depending on which 

section of the day the current reading was taken). 

 

 

Example: 

Содержание BPU321

Страница 1: ...entific 12 Information about the CE Mark 12 Symbol description s 12 EU Declaration of Conformity 12 FCC Statement 13 Blood Pressure Log Book 13 INTRODUCTION Thank you for selecting the Oregon Scientific TM BLE Upper Arm Blood Pressure Monitor BPU321 The BPU321 features multi language voice announcement and playback of blood pressure measurements for added convenience and has been designed to provi...

Страница 2: ...nformation please contact your local retailer Replacement Arm cuff Storage pouch 6V adaptor Features and accessories will not be available in all countries PRODUCT VIEW KEY FEATURES A start taking blood pressure for user 1 view user 1 measurement records view additional older records increase value of the setting toggle setting options B turn monitor on off enter setting mode confirm settings star...

Страница 3: ...Align the cover flat against the battery compartment and then slide it upwards Above diagram displays 1 Adaptor outlet 2 Battery compartment Flashing indicates monitor batteries are low Replace batteries promptly to ensure accurate readings Replace all the batteries at the same time it is dangerous to mix old and new batteries Contact your local waste disposal authority for instructions on how to ...

Страница 4: ...hysician has diagnosed you with poor circulation in your left arm use your right arm 1 Choose the position from which you wish to measure sitting or lying down 2 Roll or push up your sleeve to expose the skin 3 Put arm through the cuff loop 4 Place cuff about an inch 1 2 cm above your elbow Use cushions or other supports if necessary to adjust The air tube should run down between the inside of you...

Страница 5: ...efore starting a measurement 1 Relax your arm 2 Press to turn on the unit 3 Select user then a voice prompts you to sit in the correct position and to remain still Button User Memory Guest No records stored 1 Record stored under User 1 2 Record stored under User 2 4 Arm cuff will begin inflating automatically Digits will appear on the screen 5 Once the pressure reaches a certain level it will slow...

Страница 6: ...are steady at regular intervals An irregular heartbeat is one where there is a variance and the intervals vary If an irregular heart beat has been detected during the measurement will be displayed We highly recommend you consult your physician MOVEMENT READING ERROR If Err 1 is displayed please loosen the arm cuff and relax 2 3 minutes before taking another measurement Refer again to Preparing to ...

Страница 7: ... the corresponding user button repeatedly or to see additional records average morning evening if available or next record TIP Press and hold corresponding user button or to quickly toggle through all the entries To alternate between different user s records Press or CLEAR RECORDS When memory is full flashes Apart from deleting an entire measurement history there is also an option to delete the la...

Страница 8: ...lly At midnight everyday MANUALLY SEND DATA To prevent records from being erased we recommend users send data to their mobile device periodically When viewing records Press and hold or Successful transmission Unsuccessful transmission 8 The screen display will turn off once synchronization attempt whether successful or not has been completed Synchronizing status indicator light located above the t...

Страница 9: ...ot confuse self monitoring with self diagnosis This unit allows you to monitor your blood pressure Do not begin or end medical treatment based solely on the measurements of this device Consult a physician for treatment advice If you are taking medication consult your physician to determine the most appropriate time to measure your blood pressure Never change a prescribed medication without consult...

Страница 10: ...What are systolic pressure and diastolic pressure When ventricles contract and pump blood out of the heart blood pressure reaches its maximum value This highest pressure in the cycle is known as systolic pressure When the heart relaxes between heartbeats the lowest blood pressure is diastolic pressure Why measure your blood pressure Blood pressure measurement can highly reflect one s health condit...

Страница 11: ... HOW THE BLOOD PRESSURE MONITOR WORKS This product uses the Oscillometric Measuring method to detect your blood pressure Before every measurement the unit establishes a zero pressure equivalent to the air pressure Then it starts inflating the arm cuff to 180mmHg or higher until it senses that it has blocked your blood in the artery After that the deflation process starts during which time the unit...

Страница 12: ...1 General requirements and EN1060 3 Non invasive sphygmomanometers Part3 Supplementary requirements for electromechanical blood pressure measuring systems The CE mark further indicates that this blood pressure monitor meets the general requirements for electronic products as regards to resistance to electromagnetic interference Malfunctioning may however occur in the proximity of extremely strong ...

Страница 13: ...ry to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING This equipment complies with FCC RF radiation e...

Страница 14: ...interference received including interference that may cause undesired operation ...

Отзывы: