background image

9

GB

When the reception is complete, the radio reception signal will
stop blinking. The strength of the reception for the last full hour
will be indicated.

For better reception, place the clock away from metal objects and
electrical appliances to minimize interference.

If you wish to disable the auto-reception feature, press the (

)

button for three seconds. The radio reception signal will disappear.
The unit will not respond to radio signals.

To enable the feature again, press the (

) button for three

seconds. The radio reception signal will start blinking to initiate
reception automatically.

MODE 3.  Hour-Minute-Day of the Week (of local time)

Hour-Minute (of second time zone)

MODE 4.  Hour-Minute-Day of the Week (of second time zone)

Day-Month (of second time zone)

Press MODE, to change from one display mode to the next

Note: The bottom line of the display will be replaced by the alarm

time if the [24hr 

 OFF] button is pressed.

ABOUT RADIO RECEPTION

The BAR888A is designed to automatically synchronize its current
time and date when it is brought within range of the radio signal
from U.S. Atomic Clock.

When the BAR888 is within range, its radio-control mechanism
will override all manual settings.

When the unit is receiving radio signal, the radio reception signal
will start to blink. A complete reception generally takes about 2 to
10 minutes, depending on the strength of the radio signal.

- Strong

- Weak

- No    singal

- Receiving

Содержание BAR888A

Страница 1: ...emperature calendar clock and temperatures collected and transmitted by the remote unit The main unit can support up to three remote units The main unit is capable of keeping track of the maximum and minimum temperature of different sites And no wire installation is required As the BAR888A operates at 433MHz it can be used in the U S and most places in Continental Europe It automatically synchroni...

Страница 2: ... Enables or disables the alarms ALARM 24hr OFFBUTTON Sets the time for the alarms MODE SETBUTTON Toggles the display modes and confirms entry while setting the values for display RADIORECEPTIONSIGNAL Indicates the condition of radio reception C FSLIDESWITCH Selects between degree Centigrade C and Fahrenheit F UP BUTTON Advances the value of a setting DOWN BUTTON Decreases the value of a setting RE...

Страница 3: ...ues pressafterbatteryinsertion BATTERYCOMPARTMENT Accommodates two AAA size batteries BATTERYDOOR WALL MOUNTHOLDER Supports the remote unit in wall mounting REMOVABLETABLESTAND For standing the remote unit on a flat surface Returns all settings to default values BATTERY COMPARTMENTS Accommodates an AA size battery each RETRACKABLE TABLE STAND For standing the main unit on a flat surface BACK COVER...

Страница 4: ...on 1 Assign different channels to different remote units 2 Insert batteries for remote units before doing so for the main unit 3 Place the main unit as close as possible next to the remote unit reset the main unit after installing batteries This will ensure easier synchronization between the transmission and reception of signals 4 Position the remote unit and main unit within effective trans missi...

Страница 5: ...ylevelofthemainunitwillbeshownontheindoortemperature when it is running low HOW TO USE THE TABLE STAND OR WALL MOUNTING The main unit has a retractable table stand which when flipped open can support the unit on a flat surface Or you can flip close the stand and mount the unit on a wall using the recessed screw hole As for the remote unit it comes with a wall mount holder and a removable stand Use...

Страница 6: ...screpanciesbetweenthereading shown on the main unit and that on the respective remote unit HOW TO CHECK REMOTE AND INDOORS TEMPERATURES The indoors temperature is shown on the 3rd line of the display As for the remote sites or channels press CHANNEL to go from one channel to another The kinetic wave display on the channel number indicates the reception of that particular channel is in good order I...

Страница 7: ...search If that fails check 1 The remote unit of that channel is still in place 2 The batteries of both the remote unit and main unit Replace as necessary Note When the temperature falls below freezing point the batteries of outdoor units will freeze lowering their voltage supply and the effective range 3 The transmission is within range and path is clear of obstacles and interference Shorten the d...

Страница 8: ...ng the future 3 A SUNNY forecast covering the night time reflects fine clear weather HOW TO READ THE PRESSURE TREND The BAR888A gives you the pressure trend for the last hour It is indicated by the arrow displayed in the right hand side of the upper display An upward pointing trend arrow indicates that it is likely that the weather is improving or may be getting worse if the trend arrow is falling...

Страница 9: ... Day of the Week of local time Hour Minute of second time zone MODE 4 Hour Minute Day of the Week of second time zone Day Month of second time zone Press MODE to change from one display mode to the next Note The bottom line of the display will be replaced by the alarm time if the 24hr OFF button is pressed ABOUT RADIO RECEPTION The BAR888A is designed to automatically synchronize its current time ...

Страница 10: ...are done press MODE SET to exit The display will return to the mode last chosen HOW TO SET AND ARM THE ALARMS TheBAR888Ahastwoalarms ALARM1andALARM2 Theycan be invoked together or independently To set an alarm 1 Press 24hr OFF once to select ALARM 1 or again to select ALARM 2 The last selected time of the alarm will be displayed If you have never set the alarm before the time will be displayed as ...

Страница 11: ...ars of satisfactory service if you handle it carefully Here are a few precautions 1 Do not immerse the unit in water 2 Do not clean the unit with abrasive or corrosive materials They may scratch the plastic parts and corrode the electronic circuit 3 Do not subject the unit to excessive force shock dust tempera ture or humidity which may result in malfunction shorter electronic life span damaged ba...

Страница 12: ...h hh mm ss Day of week selectable in 4 language E F S Second time zone with date and day 2 minute crescendo alarm Power Main unit use 4 pcs UM 3 or AA 1 5V alkaline battery Remote sensing unit use 2 pcs UM 4 or AAA 1 5V alkaline battery Weight Main unit 306gm 10 79 ounces Remote sensing unit 100 gm 3 53 ounces Dimension Main unit 182 x 133 x 28 mm 7 17x5 24x1 10 inches Remote sensing unit 92 x 60 ...

Страница 13: ...mer care department at 1 800 853 8883 or via email at helpme oscientific com CAUTION The content of this manual is subject to change without further notice Due to printing limitation the displays shown in this manual may differ from the actual display The contents of this manual may not be reproduced without the permission of the manufacturer WARRANTY This product is warranted to be free of manufa...

Отзывы: