background image

EN

4

    
2.  Set the channel by pressing the 

CHANNEL

 button  

  to the required number. If you are using more than  
  one sensor, select a different channel for each  
  sensor.
3.  Slide the 

EU / UK

 switch to the setting which best  

  suits your location.
4.  Press 

RESET

.

5.  Place the sensor near the main unit.
6.  Press 

SEARCH

 to manually initiate signal sending  

  between the sensor and the main unit. The  
  reception icon on the main unit will blink for  
  approximately 3 minutes while it is searching for  
  the sensor. (Refer to the “Sensor Data    
  Transmission” section for more information.)
7.  Press the 

°C / °F

 button to select the setting you  

  want.
8.  Close the remote sensor battery compartment.
9.  Secure the sensor in the desired location using the  
  wall mount or table stand.

  To fold out the stand:

                      

1

2

   For best results:

•  Insert the batteries and select the unit, channel,  
  and radio signal format before you mount the  
  sensor.
•   Place the sensor out of direct sunlight and moisture.
•   Do not place the sensor more than 30 metres (100  
  feet) from the main (indoor) unit.
•   Position the sensor so that it faces the main  
  (indoor) unit, minimizing obstructions such as  
  doors,  walls, and furniture.
•   Place the sensor in a location with a clear view to  
  the sky, away from metallic or electronic objects.
•   Position the sensor close to the main unit  during  
  cold winter months as below-freezing  

 

  temperatures may affect battery performance  
  and signal transmission.

NOTE

 The transmission range may vary and is subject 

to the receiving range of the main unit.
You may need to experiment with various locations to 
get the best results.

SENSOR DATA TRANSMISSION

Data is sent from the sensor(s) every 60 Seconds. The 
reception icon shown in the Outdoor Temperature Area 
indicates the status.

ICON

DESCRIPTION

Main unit is searching for 
sensors.

At least 1 channel has been 
found.

Sensor 1 is sending data. 
(The number shows which 
sensor is selected.)

--- 

shows  in  Temp 

Area

The selected sensor cannot 
be found.   Search for the 
sensor or check batteries.

SELECT SENSOR CHANNEL

Press 

CHANNEL

 on the main unit, to switch between 

sensors 1-5.

                                  
The house icon shows the selected remote sensor.

To  auto-scan  between  sensors,  press  and  hold 

CHANNEL

 for 2 seconds. Each sensor’s data will be 

displayed for 3 seconds. 

To end auto-scan, press 

CHANNEL

 or 

MEMORY

.

SEARCH FOR SENSOR

To search for a Thermo sensor, simultaneously press and 
hold 

CHANNEL

 and 

MEMORY

 for 2 seconds.

NOTE

  If  the  sensor  is  still  not  found,  check  the 

batteries.

CLOCK AND CALENDAR

This product tracks the time and date based on radio-
controlled signals from the RTHR328N remote sensor, 
or manual settings that you enter.

RADIO-CONTROLLED CLOCK

The time and date are automatically updated by radio 
controlled  clock  signals  from  official  time-keeping 
organizations  in  Frankfurt  (Germany)  and  Rugby 
(England) unless you disable this feature. The signals 
are  collected  by  the  remote  sensor  (RTHR328N) 
whenever it is within 1500 km (932 miles) of a signal.

Initial reception takes 2-10 minutes, and is initiated when 
you first set up the unit, and whenever you press 

RESET

Once complete, the reception icon will stop blinking.
The  reception  icon 

  shown  in  the  Clock Area 

indicates 2 factors:

BAR283_EN.indd   4

3/17/06   6:33:43 PM

P/N: 086L004374-016_EN REV1

5/10

Содержание BAR283

Страница 1: ...Jumbo Weather Station Model BAR283 User Manual P N 086L004374 016_EN REV1 1 10...

Страница 2: ...step instructions as well as technical speci cations and warnings you should know Jumbo Weather Station Model BAR283 USER MANUAL CONTENTS Introduction 1 Product Overview 2 Front View 2 Back View 2 LCD...

Страница 3: ...um minimum and current readings 3 Weather Forecast Area Animated weather forecast 4 Outdoor Temperature Area Maximum minimum and current readings sensor channel number Clock Alarm Calendar Area 1 2 3...

Страница 4: ...ttery change To install the main unit batteries NOTE Do not use rechargeable batteries shows when batteries are low UNIT LOCATION Main Clock Alarm Calendar Area Remote Sensor Outdoor Temperature Area...

Страница 5: ...periment with various locations to get the best results SENSOR DATA TRANSMISSION Data is sent from the sensor s every 60 Seconds The reception icon shown in the Outdoor Temperature Area indicates the...

Страница 6: ...icon will NOT appear on the display SET CLOCK You only need to do this if you have disabled the radio controlled clock or if you are too far from a RF signal 1 Press and hold MODE LIGHT for 2 seconds...

Страница 7: ...rometric pressure trend readings The LCD display shows an animated icon indicating the forecasted weather WEATHER FORECAST ICONS ICON DESCRIPTION Day Night Clear Day Night Partly cloudy Cloudy Rainy S...

Страница 8: ...separately for special treatment is necessary NOTE The technical speci cation of this product and contents of this user manual are subject to change without notice Images not drawn to scale TROUBLESHO...

Страница 9: ...the information you need on our website however if you re in the US and would like to contact the Oregon Scienti c Customer Care department directly please visit www2 oregonscienti c com service defau...

Страница 10: ...2006 Oregon Scientific All Rights Reserved 086L004374 016 P N 086L004374 016_EN REV1 10 10...

Отзывы: