BATTERY INSTALLATION:

REMOTE UNIT

The remote unit uses two UM-4 or “AAA” size alkaline batteries.

Installation:

1. Remove the screws on the battery compartment.

2. Select the desired temperature scale by switching the °C/°F

switch located inside the battery compartment.

3. Select the channel number on the CHANNEL slide switch. Note

that once a channel is assigned to a remote unit, you can only
change it by removing the batteries or resetting the unit.

4. Insert the batteries strictly according to the polarities shown

inside the battery compartment.

5. Replace the battery compartment door and secure the screws.

Note: Disposed of improperly, batteries can be harmful.

Protect the environment by taking exhausted batteries to
authorized disposal stations.

BATTERY INSTALLATION: MAIN UNIT

1.  Gently lift the tab on the battery compartment door.

2.  Insert four UM-3 or “AA” size alkaline batteries.

3.  Replace the battery compartment door.

Note: For both the remote sensor and the main unit, replace batteries when

they are low. The low battery indicator [

] in the indoor or / and outdoor

temperature window will be displayed when the batteries are low.

HOW TO READ THE KINETIC

WAVE DISPLAY

The kinetic wave display shows the signal receiving status of the
main unit. There are three possible forms:

The unit is in searching mode.

Channel registered in search mode.

No signal received in search mode.

Содержание BAR112

Страница 1: ...is unit has a large four line liquid crystal display LCD for displaying weather forecast information in outdoor temperatures a radio frequency RF controlled calendar clock time zone adjusted time and dual daily alarms Also it can display temperature readings from up to three wireless remote thermo sensors Otherfeaturesincludeaday of the weekdisplayinfourabbreviated languages a four step crescendo ...

Страница 2: ...arm times Current time and date in another time Zone Radio Frequency RF status indicator ALARM ON icon indicates when the alarm is active Alarm indicator B CONTROL BUTTONS B1 CHANNEL BUTTON Sets the remote sensor channel B2 MEM BUTTON Displays minimum and maximum temperature readings and erases memory data B3 ALARM BUTTON Displays the alarm time or changes the alarm set time B4 MODE SET BUTTON Cha...

Страница 3: ...ote unit on a flat surface BEFORE YOU BEGIN For best operation Insert batteries for the remote unit first Then proceed with inserting the batteries for the main unit Position the remote unit and the main unit within effective transmission range In usual circumstances the effective range is 30 meters Though the remote unit is weather proof it should be placed away from direct sunlight rain or snow ...

Страница 4: ...r and secure the screws Note Disposed of improperly batteries can be harmful Protect the environment by taking exhausted batteries to authorized disposal stations BATTERY INSTALLATION MAIN UNIT 1 Gently lift the tab on the battery compartment door 2 Insert four UM 3 or AA size alkaline batteries 3 Replace the battery compartment door Note For both the remote sensor and the main unit replace batter...

Страница 5: ...URES The maximum and minimum recorded temperatures will be automatically stored in memory To display them press MEM Press MEM again to alternate between the maximum minimum and current temperatures The respective MAX or MIN indicator will be displayed To clear the memory press MEM button and hold for three seconds The maximum and minimum recorded temperatures will be erased Subsequently if you pre...

Страница 6: ...ch press on the MODE button will toggle the display in the above order Note The bottom line of the display will be replaced by the alarm time if the ALARM SET button is pressed ABOUT RADIO RECEPTION The BAR112 is designed to automatically synchronize its calendar clock once it is brought within range of the Frankfurt DCF77 radio signal When the BAR112 is within range its radio control mechanism wi...

Страница 7: ... set the minutes hour current date month display language day of week and offset for the alternate time zone Note The time and date are displayed in 24 HOUR clock format For the language display you can choose among English E German D French F and Italian I Day of week is in the usual sequence of Monday through Sunday For the alternate time zone which is indicated by the ZONE icon enter the hour o...

Страница 8: ... press button or AL ON OFF button Pressing will stop the alarm which is still armed and will activate at the set time the following day If ALON OFF buttonispressedinstead thealarmwillbestopped and deactivated all together NOTE ON OUTDOOR REMOTE TEMPERATURE Once batteries are in place in the remote unit it will start transmitting samplings at 30 second intervals If no signals are received when the ...

Страница 9: ...er dry it immediately with a soft lint free cloth 2 Do not clean the unit with abrasive or corrosive materials Abrasive cleaning agents may scratch the plastic parts and corrode the electronic circuit 3 Do not subject the unit to excessive force shock dust temperature or humidity Such treatment may result in malfunction a shorter electronic life span damaged batteries or distorted parts 4 Do not t...

Страница 10: ...cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful inter ference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following meas ures SPECIFICATION...

Страница 11: ... technician for help CAUTION The content of this manual is subject to change without further notice Due to printing limitation the displays shown in this manual may differ from the actual display The manufacturer and its suppliers held no responsibility to you or any other person for any damage expenses lost profits or any other claim arise by using this product The contents of this manual may not...

Страница 12: ... GB MODEL BAR112 DIGITAL WEATHER FORECASTER WITH REMOTE THERMO SENSOR AND RADIO CONTROLLED CLOCK Instruction Manual Mode D emploi Bedienungsanleitung Manuale di Istruzioni Instrucciones de Funcionamiento ...

Отзывы: