Troubleshooting Guide

6.

Check the voltage to and from the switch when activated.  You should be able to 
measure line voltage entering and leaving the switch when activated.

7.

Check the switch plate cover.  The plate must sit squarely on the bearing wall 
and the cabinet base.

2.

If the motor operates but the green “cleaning air” light does not operate: 

a. Remove the cell and check to see if the “cleaning air” light comes on.

b. If the light operates with the cell removed, check the cell for broken wires that 

could cause a dead short. Check to see if the cell plates are bent or touching. 
Check to see if there is a foreign object in the cell. Check for carbon paths or 
tracks on the cell ends.

If the switch plate cover is 
not secure, it will prevent the
top from engaging the 
interlock switch.  Insure that 
the cover is in position.

If the cell has loose or broken wires or bent plates,
replace the cell.  If there are no loose or broken
wires present, hold the cell up to the light and look
for metal shavings or anything that may be causing
a short.  If nothing is apparent, clear and retest the
cell.  If the problem persists, replace the cell. If carbon
tracking is present on cell ends, replace the cell.

CLEANING AIR LIGHT

TO SWITCH, If voltage is 
present on line side of the 
switch but not present on 
load side, the switch is bad.
FROM SWITCH, If there is no
voltage on line side of the 
switch, check the wall outlet.
If there is voltage at the 
outlet, then the line cord is 
bad.

LINE SIDE

LOAD SIDE

Содержание 447628

Страница 1: ...S I M P L Y A M A Z I N G Service Manual Table Top Air Cleaner Super Air 5 Air 6 Model 447628 4478801 REV I Please disregard all earlier versions...

Страница 2: ...ervicing Tools Required Multimeter Fluke Model 8024 B High Voltage Probe Fluke Model 80K 40 2 Flat Blade Screwdriver 2 Phillips Drive Screwdriver Diagonal Wire Cutters Wire nuts Needlenose Pliers Gene...

Страница 3: ...ceive a positive electrical charge as they pass through the ionizing section The positive charged particles then enter the collecting section which uses a series of alternately charged aluminum plates...

Страница 4: ...gative ion generator tip with a alcohol and a cotton swab 7 Clean the dirt and grime from the motor shaft using a soft cloth 8 Squirt a few drops of machine oil 3 in 1 type oil not WD 40 type oil in t...

Страница 5: ...unit b With the top removed depress the interlock switch with a plastic handle screwdriver to test operation c If the motor and blower operate then the problem is that the interlock switch is not enga...

Страница 6: ...erly seated in the bracket or is the bracket broken or distorted The switch is held in position by a bracket that allows the switch to be snapped between two locator ribs on the bracket 5 Are the wire...

Страница 7: ...k for carbon paths or tracks on the cell ends If the switch plate cover is not secure it will prevent the top from engaging the interlock switch Insure that the cover is in position If the cell has lo...

Страница 8: ...ssed The voltage should measure from 5 5 KVDC to 7 0 KVDC An alternate method to check voltage is by using a plastic handled screwdriver to short the high voltage contacts and observe a spark Option 2...

Страница 9: ...to try to spin the blower wheel c Turn the unit over and check for signs of distortion in the cabinet bottom beneath the motor that might prevent the blower from spinning The stripper is held in posi...

Страница 10: ...o remedy this a Clean the dirt and grime from the motor shaft using a soft cloth b Squirt a few drops of lubricating oil 3 in 1 type oil not WD 40 type oil in the slot on the shaft to lubricate the be...

Страница 11: ...cket normally indicates motor overheating The motor should be replaced Insure that the isolator pads are in position Replace if the motor moved while being held in place with mounting bracket The outb...

Страница 12: ...ove the cell and wash with warm soapy water Dry completely before re installing c If there are bent cell plates d If the cell is improperly installed in the unit e If the cell contacts are broken or l...

Страница 13: ...present the ionizer is OK b If voltage is not present check HV power supply c If voltage is present at HV power supply but not the needle Clean needle with alcohol and a cotton swab See above diagram...

Страница 14: ...__________________________ _____________________________________________________________________________ _____________________________________________________________________________ _________________...

Страница 15: ...and Blower Wheel Removal and Replacement page 22 Led Assembly Removal and Replacement page 23 Cell Assembly Removal and Replacement page 23 Ionizer Needle Removal and Replacement page 23 Fan Blade Re...

Страница 16: ...the bearing wall locator seat and then remove the stripper 4 Flip the unit onto its side with the bearing wall up and release the two locking tabs for the bearing wall assembly by using a regular scre...

Страница 17: ...hed to the motor 6 Remove the power supply cover by placing a screwdriver blade in the cover slot with the blade inserted on the blower wheel side of the slot Catch the tan snap tab and twist the scre...

Страница 18: ...black terminal 1 wires from the selector switch by pushing a paper clip straightened under the wire into the switch while pulling on the wire lightly 10 Remove the white motor wire from the power supp...

Страница 19: ...age INSULATOR BOARD WARNING The unit has been designed with special insulator and isolator spacer boards that must be in position These boards are made of a special insulator material and must be in p...

Страница 20: ...ternal electrical wiring away from the rotating elements Failure to allow for proper clearance for rotating members can cause electric shock personal injury or property damage 4 The power supply cover...

Страница 21: ...n working on it with line voltage applied Failure to practice normal electrical safety precautions can cause electrical shock personal injury or property damage ROTATING ELEMENT WARNING Unit has a rot...

Страница 22: ...must be clean before installing the new blower wheel and grommet Using a razor knife carefully remove any sealant on the shaft and wipe it with a clean cloth 3 You are now ready to reinstall the new...

Страница 23: ...ce with a new cell 3 Reverse the above step 1 to replace the cell Ionizer Needle Removal and Replacement 1 Follow steps 1 3 and 6 of Motor Removal and Replacement EXTREME HIGH VOLTAGE WARNING This equ...

Страница 24: ...3 and 6 of Motor Removal and Replacement ROTATING ELEMENT WARNING Unit has a rotating blower wheel and cooling fan to circulate air and keep the unit cool When servicing the unit and repairing the un...

Страница 25: ...OP GRAY 1 12 442415 101 COLLECTOR CELL 1 13 142475 001 ION NEEDLE ASSEMBLY 1 14 342228 001 STRIPPER 1 15 342227 001 MOTOR MOUNTING BRACKET 1 16 136483 001 DRIVE GROMMET 1 17 342402 251 HV POWER SUPPLY...

Страница 26: ...RN RED BLUE 242477 035 ION COLL CELL POWER BOOST SWITCH BLUE 242477 035 CONTACT WALL GRN GRN BLACK RIBBED BRN MED RED LO BLACK RIBBED 120V 60HZ POWER SWITCH OUTPUT POS 1 OFF POS 2 L 1 POS 3 L 1 4 POS...

Страница 27: ...__________________________ _____________________________________________________________________________ _____________________________________________________________________________ _________________...

Страница 28: ...2004 Oreck Holdings LLC All rights reserved All trademarks are owned and used under the authority of Oreck Holdings LLC 75422 01 REV I 08 04 R 7693 R 7695...

Отзывы: