Oreck 2005HH Скачать руководство пользователя страница 7

7

WARNING: Unplug cord from electrical
outlet before servicing.

Under certain conditions it is possible to stuff or block the intake
tube and the lower tube assembly. If your vacuum cleaner does
not pick up properly, or makes unusual noise and the outer bag
does not fluff up or balloon open, follow the following steps:

1. Check for blockage at the

mouth of the intake
opening. See illustration A.
If there is blockage, remove
it with long-nose pliers, a
screwdriver or coat hanger.
If you can not reach the
blockage, remove
baseplate. See illustration B.

2. If the blockage is not at the

base, remove lower tube.
See illustration C. Unhook
retainer spring, releasing
bottom of bag. Twist lower
collar counterclockwise to
slide up. Pull tube out of
base. Check for blockage.
If blockage is in the tube,
remove with a coat hanger.

3. If tube is not blocked, look

into fan housing. See illus-
tration D. Remove debris
with long-nose pliers, a
screwdriver or coat hanger.

4. To reassemble, check O-ring

on tube, and replace if
damaged. Vacuum will not
operate properly without the
tube O-ring. Slide O-ring to
approximately 2" from base
of tube. Replace tube by
first lining up slot at base of
tube with inner tab inside
fan housing. Then reinsert
tube and push down until
the tube is seated. Make
sure O-ring is in place
against fan housing
opening. Replace and
tighten collar until collar
locking tabs are locked in
place. See illustration E.
Make sure collar is not cross
threaded on housing.

C

Retainer 

Spring

Intake Opening

A

D

O-ring

Fan

Housing

E

WARNING: Unplug cord from
electrical outlet before servicing.

T

A

djust or 

R

eplace 

B

rush

To determine if the brush is
worn, place a firm straight
edge across the  nozzle
opening. If brush bristles
do not extend beyond
baseplate, brush should be
adjusted.

Remove the baseplate by
removing 5 screws. Then,
remove the belt and brush
roll from the housing.

Rotate both bearing assem-
blies at ends of brush roll
to show “OLD” and
replace in the holding
channels in the housing.

NOTE: The bearing
assembly setting marked
“OLD” has a smooth side.
The one marked “NEW”
has a notch. When
rotating bearings, make
sure both bearing
assembly settings are the
same and face up when
replacing the brush roll.

Reassemble the belt and
the baseplate and check
bristle height above
baseplate at each end of
brush.

If a previous adjustment
has already been made
and bristle height does not
extend above baseplate, a
new brush assembly
should be ordered.

IMPORTANT: Unless
the brush is worn as
indicated above,
both bearings must
be in the “NEW”
position. When
rotating, both
bearings must be in
the ”OLD” position.
Unmatched settings
will cause damage
to your machine. 

Rotate and match

bearing assemblies

S

tuffing or 

B

lockage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 2005HH

Страница 1: ...G USER S GUIDE IMPORTANT SAVE THIS BOOKLET Includes Safety Warnings Warranty Operating Instructions Trouble Diagnosis Accessories 2005HH 2005RH COMMERCIAL HIGH SPEED UPRIGHT VACUUM CLEANER WITH CLEANI...

Страница 2: ...t let the unit run while in any one stationary position for any period of time Keep the unit moving while in operation Do not allow to be used as a toy Close attention is necessary when used by or nea...

Страница 3: ...lving roller brush for thirty 30 days from the date of purchase This warranty does not cover the replacement of expendable or consumable parts such as carbon motor brushes edge brushes belts bulbs dis...

Страница 4: ...assembling your cleaner the parts have been numbered as follows 1 Handle section upper 2 Tube lower 3 Power head 4 Outer bag 5 Paper filter dust bag 6 Power cord 7 Retaining spring 8 Bag tension bar...

Страница 5: ...ning cannot take place regardless of the cleaner s power To keep your cleaner operating at maximum efficiency change the dust bag frequently DO NOT FILL ABOVE THE LINE INDICATED ON THE DUST BAG Be sur...

Страница 6: ...he base of the cleaner could be damaged if used on concrete or abrasive surfaces and therefore cause damage to wood floors soft vinyl asphalt tile etc floor surfaces and polished floor finishes The ro...

Страница 7: ...is seated Make sure O ring is in place against fan housing opening Replace and tighten collar until collar locking tabs are locked in place See illustration E Make sure collar is not cross threaded on...

Страница 8: ...truction Replace belt See To Adjust or Replace Brush Clear obstruction Change bag Return to Service Center for repair Check brush roll end cards Make sure words OLD or NEW match at each end PROBLEM PO...

Отзывы: