background image

27

(56)

Ins
talling the Sho

w

er Unit

Electrical installation should be 

performed according to local regulations 

by a licensed electrician.

Содержание Oas

Страница 1: ...Oas Indo Shower Unit Installation Oas Indo EU 190528 ...

Страница 2: ...2 56 Introduction Safety Messages This manual applies to model OS8732 Ei2 ...

Страница 3: ...ential of the shower please read and follow the procedures in this manual Make sure that you fully understand how to operate this shower and make sure that it is properly maintained in accordance with the instructions given in this manual Do not throw this manual away keep it handy for future reference ...

Страница 4: ...y lead to scalding and risk of injury Never permit or operate electrically connected devices in or within 15 cm of the shower system Cleaning and user maintenance shall not be completed by children Do not operate the shower system if water leaks from the appliance Do not operate the shower system if it is frozen or suspected of being frozen Unauthorized modification of internal components and wiri...

Страница 5: ...n system or damage the shower system Do not drink the shower water The system has several functions for cleaning the water as well as intelligent hygiene operation modes but drinking water quality cannot be guaranteed To reduce the risk of contracting a waterborne illness you should always follow the cleaning and maintenance procedures in this manual We cannot provide a 100 guarantee against the r...

Страница 6: ... All electrical installations must conform to local regulations and be performed by a licensed electrician All plumbing installations must conform to local regulations and be performed by a licensed plumber This is an earthed appliance the connection to the earth circuit is mandatory The appliance shall be supplied through a class A GFCI ground fault circuit interrupter The appliance shall be supp...

Страница 7: ...nty does not cover Defects arising out of materials or a design specified by the Client or by any alterations carried out without our consent Defects that appear under conditions of operation not provided for and under improper use of the product Defects caused by faulty maintenance incorrect installation or a faulty repair Repairs should be carried out only by Orbital Systems one of our certified...

Страница 8: ...ilable to assist you should you require product advice experience any problems need to purchase spare parts or to set up a service visit We recommend your first point of contact should be your installer who will be able to offer all of the above services Alternatively you can also contact Orbital Systems who will be able to assist you Repairs should always be carried out only by Orbital Systems or...

Страница 9: ...9 56 TA B L E OF CONTENTS Installing the Shower Unit 10 Installing the Shower Head 46 WiFi Setup Track your Savings 53 Installing the Hand Shower 54 ...

Страница 10: ...10 56 INSTALLING THE SHOWER UNI T watch video https bit ly 2QNFVLP ...

Страница 11: ...7 18 Hose Connection Indo Core Indo Panel Panel Lock Magnetic Key Funnel Smart Sensor Unit Sensor Tank Sensor Cable Recirculation Hose Flush Hose Smart Sensor Lock half thread M4 3 Hex x1 full thread M4 3 Hex x1 WiFi Cable and Antenna Air Gap Tank Quartz Glass UV Lamp Filter Capsule Descaling tablet Control Dial Installing the Shower Unit ...

Страница 12: ...12 56 Installing the Shower Unit Remove Panel Template x8 M3 5 5mm driver ...

Страница 13: ...13 56 Installing the Shower Unit ...

Страница 14: ...14 56 270 mm Installing the Shower Unit ...

Страница 15: ...15 56 Installing the Shower Unit Apply lubricant ...

Страница 16: ...16 56 Installing the Shower Unit x1 Half thread M4 3 Hex If Tube Lock is misaligned it can cause issues in further installation steps ...

Страница 17: ...17 56 Installing the Shower Unit x1 Full thread M4 3 Hex ...

Страница 18: ...18 56 Installing the Shower Unit Tighten with pliers to secure water tightness ...

Страница 19: ...19 56 Installing the Shower Unit ...

Страница 20: ...20 56 Make sure Smart Sensor Unit is inserted correctly The O ring should not be visible Installing the Shower Unit ...

Страница 21: ...21 56 Installing the Shower Unit ...

Страница 22: ...22 56 Installing the Shower Unit ...

Страница 23: ...23 56 Installing the Shower Unit ...

Страница 24: ...24 56 Installing the Shower Unit ...

Страница 25: ...25 56 Installing the Shower Unit x1 M8 Socket Head ...

Страница 26: ...26 56 Installing the Shower Unit Make sure to have correct alignment against thread ...

Страница 27: ...27 56 Installing the Shower Unit Electrical installation should be performed according to local regulations by a licensed electrician ...

Страница 28: ...28 56 Installing the Shower Unit Provided by client ...

Страница 29: ...29 56 Installing the Shower Unit ...

Страница 30: ...30 56 Installing the Shower Unit ...

Страница 31: ...31 56 Installing the Shower Unit ...

Страница 32: ...32 56 Installing the Shower Unit ...

Страница 33: ...33 56 Installing the Shower Unit Mount Indo Panel x8 M3 5 5mm driver ...

Страница 34: ...34 56 Make sure the gasket is placed in the circular groove Installing the Shower Unit ...

Страница 35: ...35 56 Installing the Shower Unit ...

Страница 36: ...36 56 x3 M4 Hex 2 5 mm Installing the Shower Unit ...

Страница 37: ...37 56 Installing the Shower Unit ...

Страница 38: ...38 56 Make sure to have correct alignment against thread Installing the Shower Unit ...

Страница 39: ...39 56 Installing the Shower Unit ...

Страница 40: ...40 56 Installing the Shower Unit ...

Страница 41: ...41 56 Installing the Shower Unit ...

Страница 42: ...42 56 Installing the Shower Unit ...

Страница 43: ...43 56 Adjust Indo Panel angle Installing the Shower Unit Secure Adjust x2 M3 nut x2 M3 nut ...

Страница 44: ...44 56 Installing the Shower Unit Adjust Indo Panel depth ...

Страница 45: ...45 56 Installing the Shower Unit Shower Unit installed Next step Installing the Shower Head ...

Страница 46: ...46 56 INSTALLING THE SHOWER H E AD ...

Страница 47: ...47 56 5 4 1 2 3 1 2 3 4 5 COM PONE NT OVERVIEW Installing the Shower Head Shower Head Arm Shower Head Shower Water Connector Wall Mount Disc Shower Head Wall Mount ...

Страница 48: ...48 56 2 mm It is recommended to cut the Angle Wall Box with the LK Wall Box Cutter UNI Installing the Shower Head ...

Страница 49: ...49 56 Cover both ends of the Shower Water Connector with teflon tape to avoid leakage Installing the Shower Head ...

Страница 50: ...50 56 Screw the Shower Head Wall Mount flush to the wall or leakage may occur Installing the Shower Head ...

Страница 51: ...51 56 Apply lubricant to PEX Hose inside of Shower Head Arm Installing the Shower Head ...

Страница 52: ...52 56 Installing the Shower Head Shower Head installation completed ...

Страница 53: ... TRACK YOU R SAVI NGS Insert Filter Capsule as instructed in the chapter Changing the Filter WiFi Setup For WiFi setup please contact support orbital systems com Europe CET 46 0 40 619 55 50 Insert Quartz Glass as instructed in the second half of the chapter Cleaning the Quartz Glass Insert UV Lamp as instructed in the second half of the chapter Changing the UV Lamp ...

Страница 54: ...54 56 INSTALLING THE HAND SHOWE R ...

Страница 55: ...55 56 1 2 1 2 Hand Shower Shower Hose COM PONE NT OVERVIEW Installing the Hand Shower ...

Страница 56: ...56 56 Installing the Hand Shower ...

Страница 57: ...C E R T I F I E D S PA C E T E C H N O L O G Y ...

Отзывы: