background image

HOSE CONNECTIONS

1

Provided by Customer

1.

2.

CAUTION

Install hose connections accord-
ing to local regulations and
adaptations.

3.

Installation

17

Содержание OAS R3

Страница 1: ...INST ALLATION O A S W A L L I N T E G R A T E D R 3 5 06 0012 Publication date 2020 02 27 ...

Страница 2: ...cument may be reproduced or copied in any form or by any means without written permission from Orbital Systems The English language version of this document contains the original in structions All other language versions are translations of the original instructions ...

Страница 3: ...Installing the Shower Unit 9 Sensor Cable Flush Hose and Recirculation Hose 9 Sensor Lock 10 Smart Sensor Unit and Sensor Tank 12 Funnel 14 Shower Unit Core 14 Hose Connections 17 Air Gap Tank 18 Control Dial 18 Next Step 21 Installing the Shower Head 22 Installing the 3rd Party Shower Head 24 Installing the Hand Shower 25 Installing the Diverter and Hand Shower 25 Installing the Hand Shower Holde...

Страница 4: ...This page is intentionally left blank ...

Страница 5: ...0 328 v2 1 1 EN 301 489 1 v2 1 1 EN 301 489 17 v3 1 1 EN 300 330 v2 1 1 EN 62311 2008 EN 60335 2 105 2005 A1 A11 Additional standard that has been applied to the product UL 1951 IGC 330 18 FCC Part 15 B EN 1717 BBR NSF55 EN 13076 The product has undergone mandatory or voluntary certification procedures in order to receive the following certifications KIWA TG 1503 KIWA K100686 01 IAPMO E10059 IAPMO...

Страница 6: ...e the shower to clean extreme soil ing or pour corrosive chemicals or cleaners down the shower drain Any other use of the system could seriously deteriorate the quality of the filtration system or damage the show er system Do not drink the shower water Quality of the water is not guaranteed to meet drinking wa ter quality These instructions are provided to advise the best practice for the installa...

Страница 7: ...led under strict standards Orbital Systems warranty covers defects which appear within a period of two years from delivery of the product Orbital Systems warranty does not cover Defects arising out of materials or a design specified by the Customer or by any alter ations carried out without our consent Defects that appear under conditions of operation not provided for and under im proper use of th...

Страница 8: ...should you require product advice experience any problems need to purchase spare parts or to set up a service visit Repairs should always be carried out only by Orbital Systems Contact us support orbital systems com www orbital systems com Europe CET 46 0 40 619 55 50 Installation 4 ...

Страница 9: ...00 mm 812 mm 440 mm Ø 75 mm 600 mm 0 mm OS Head Hand Shower 1000 mm INFORMATION VALID FOR ALL SHOWER VARIANTS Picture displaying OS Head Hand Shower variant 2190 mm 575 mm 150 mm 1266 mm 2190 mm 150 mm 1266 mm 184 mm 122 mm 145 mm 3rd Party Shower Ø 50 mm 1540 mm Installation 5 ...

Страница 10: ... 2 4 GHz required Circuit breaker One per shower required Plumbing Water Hot and Cold Water Inlet Separate hot cold inlet required 1 2 BSPP G pipe connection needed Temperature of inlet water Cold 4 C to 30 C Hot 55 C to 70 C Water inlet flow Min 9 litres minute hot and cold Water pressure Min 3 bar 43 5 psi 0 3 MPa measured at the highest point of installation Max pressure 10 bar 145 psi 1 MPa Ha...

Страница 11: ...Core Wall Enclosure HxWxD 932 x 538 x 145 mm Available Shower variants A OS Head Hand Shower B OS Head Shower C 3rd Party Shower 4 5 6 8 3 2 1 7 1 Shower Unit Core 2 Core Wall Enclosure 3 Control Dial 4 Shower Head 5 Hand Shower 6 Hand Head Diverter 7 Drain Unit 8 Smart Sensor Unit and Sensor Tank Installation 7 ...

Страница 12: ...GESTION Recommended installation A fully enclosed shower space with floor heating is recommended to optimize recircu lation rates INFORMATION VALID FOR ALL SHOWER VARIANTS Picture displaying OS Head Hand Shower variant Installation 8 ...

Страница 13: ...se 10 Flush Hose 11 Smart Sensor Lock half thread M4 3 Hex x1 full thread M4 3 Hex x1 12 Air Gap Tank 13 Quartz Glass 14 UV Lamp 15 Filter Capsule 16 Cleaning Tablet 17 Control Dial 18 WiFi Cable and Antenna SENSOR CABLE FLUSH HOSE AND RECIRCULATION HOSE 8 9 10 1 Install Sensor Cable Flush Hose and Re circulation Hose Make sure the Sensor Cable goes first and that the connector protection cover is...

Страница 14: ...ENSOR LOCK 11 1 NOTICE Apply lubricant Connect hoses to the Sensor Lock 2 3 x1 Half thread M4 3 Hex CAUTION If Sensor Lock is misaligned it can cause issues in further instal lation steps Installation 10 ...

Страница 15: ...in sert it into the Drain Pipe Push it all the way in 5 Rotate until parallel with the floor of the Drain Bowl 6 x1 Half thread M4 3 Hex CAUTION Do not overtighten Tighten Screw until it just reaches the floor of the drain bowl Installation 11 ...

Страница 16: ...o avoid damage CAUTION Make sure to have correct align ment between key and slot in connectors Insert Smart Sensor Unit Cable through hole in Sensor Tank and connect with Sensor Cable 3 Insert Sensor Tank and connect Smart Sensor Unit with Sensor Lock Make sure Sensor Lock is in Open position 4 CAUTION Place cable towards the wall of the drain to avoid damage Installation 12 ...

Страница 17: ...5 CAUTION Make sure Smart Sensor Unit is inserted correctly The red O ring should not be visible Set Sensor Lock to Locked position Installation 13 ...

Страница 18: ...UNNEL 5 NOTICE Placing the Funnel with the hole ori ented to the right will cause the Oas system to not recirculate water SHOWER UNIT CORE 2 1 Remove transport plugs before installa tion Installation 14 ...

Страница 19: ...lting the Shower unit CAUTION Make sure that hoses and cables are not pinched Insert Core into Core Wall Enclosure and attach Safety Wire Keep tilted to enable electrical installation 3 WARNING Electrical installation should be performed according to local regulations by a licensed electri cian 4 Installation 15 ...

Страница 20: ...5 x1 M8 Socket Head 6 CAUTION Make sure to have correct align ment between key and slot in connectors Installation 16 ...

Страница 21: ...HOSE CONNECTIONS 1 Provided by Customer 1 2 CAUTION Install hose connections accord ing to local regulations and adaptations 3 Installation 17 ...

Страница 22: ...AIR GAP TANK 12 CONTROL DIAL 17 1 Position the Control Dial according to the Up marking before assembly Installation 18 ...

Страница 23: ...2 CAUTION Risk of damage to panel door if overtightening x4 Plastite screw 12 mm 3 4 CAUTION Make sure to have correct align ment between key and slot in connectors Installation 19 ...

Страница 24: ...5 Adjust Wall integrated Panel angle 6 Adjust x4 M3 5 5 mm driver Secure Installation 20 ...

Страница 25: ...details 1 Shower Unit installation completed 2 Next step depends on Shower variant Follow steps valid for OS Head Shower Installing the Show er Head 22 Follow steps valid for 3rd par ty Shower Installing the 3rd Par ty Shower Head 24 Follow steps valid for OS Hand Shower Installing the Diverter and Hand Shower 25 Instal ling the Hand Show er Holder 27 and Installing the Hand Shower 25 Installation...

Страница 26: ...iew 3 2 1 1 Shower Head Wall Mount 2 Shower Head Arm 3 Shower Head 1 It is recommended to cut the Wall box UNI Push with the LK Wall Box Cutter UNI 2 2 mm 3 NOTICE Cover the end of the Shower Wa ter Connector with thread seal ant to avoid leakage Installation 22 ...

Страница 27: ...4 5 Shower Head installation completed Installation 23 ...

Страница 28: ...I N S T A L L I N G T H E 3 R D P A R T Y S H O W E R H E A D Install third party shower head according to local regulations Installation 24 ...

Страница 29: ... 5 11 8 6 7 2 1 12 13 1 Diverter Valve House 2 Diverter Wall Plate 3 Diverter knob 4 MC6S M4x8H A2 Hexagon Screw x3 5 Diverter Housing Cover 6 T25 Screw 32mm 4 8mm 7 T25 Screw 50mm 5 5mm 8 Drilling Template 9 T8 2 5x8mm Screw 10 Torx T8 L Key Tool 11 Diverter Bottom Cap 12 Hand Shower 13 Shower Hose Installation 25 ...

Страница 30: ...Place template over protruding PEX Hoses Level the template according to instructions on template Drill 4 holes 6 mm in marked locations 3 18 mm x1 x1 T25 Screw 50 mm T25 Screw 32 mm CAUTION Seal drill holes according to local regulations CAUTION It s important that the PEX Hoses are pushed in all the way to stop before cutting 4 x2 MC6S M4x8H A2 Hexagon Screw Installation 26 ...

Страница 31: ...5 6 x1 MC6S M4x8H A2 Hexagon Screw 7 NOTICE Use Torx T8 L key tool in kit x1 T8 2 5x8mm Screw INSTALLING THE HAND SHOWER HOLDER Component Overview 3 2 1 5 4 Installation 27 ...

Страница 32: ...nd Shower Bracket 4 T25 Screw 32mm 4 8mm 5 M4x8 Set Screw 1 x1 x1 T25 Screw 50 mm T25 Screw 32 mm 2 NOTICE Use Torx T8 L key tool in kit Push Hand Shower Cover into position use Set Screw to lock 3 Hand Shower installation completed Installation 28 ...

Страница 33: ...Systems iOS app from Apple app store and create an User account It is recommended to always use the latest available version SETUP WIFI Settings Add Shower WIFI Settings Support Log out Click Wifi settings and follow instructions ADD SHOWER Settings Add Shower WIFI Settings Support Log out Click Add shower and follow instructions Installation 29 ...

Страница 34: ...This page is intentionally left blank ...

Страница 35: ...C E R T I F I E D S P A C E T E C H N O L O G Y ...

Отзывы: