LRD-200B Low-Rate Demodulator
LRD-200B Low-Rate Demodulator
©
Copyright 2012, Orbital Systems, Ltd.
17
Revision B.03
2.3.4
Earth Ground
The LRD-200B has an earth ground connector located near the power on/off
switch. Refer to local electrical codes and system documentation to determine
when to use earth ground (see Figure 5).
2.3.5
Data Connections
The LRD-200B NRZ data and clock connections are located on the rear panel.
These connections have RS-422, LVDS, and 50-ohm TTL interfaces (see
). These interfaces are active and can be used simultaneously.
Figure 8 - Data Connections
When used with an Orbital Systems, Ltd. front end server, pre-configured
cables are provided for J04. Plug the cable into J04, and secure it using the
screws retained in the connector (see Figure 9).
Figure 9 - Pre-Configured Cable and Connector With Screws
Orbital Systems, Ltd. systems use either the RS-422 or LVDS signals. All new
systems use LVDS.
Содержание LRD-200B
Страница 68: ......