ENGLISH
25
Strip _” (6mm) of the plastic insulation off the end of each wire.
Determine which valve you want to connect to which station. Connect each
valve wire to its station terminal (labeled 1-6) by inserting the bare wire fully
into the terminal.
It will be necessary to open the terminal to allow for wire insertion or removal.
To do this you will need to use a small phillips head screwdriver.
Connect the common wire to the terminal labeled "com" [See Figure 17].
Connecting the Transformer
With the wiring terminal shroud off, find the two terminal holes labeled "24vac".
Make sure the transformer is not plugged in. Insert one of the two power leads
from the transformer into each terminal.
Figure 17: Connceting Valve Wires
24V 24V
COM
1
2
3
4
5
6
PUMP
To Station Valve
WTM230052 57194-24 rD 12/13/2002 11:28 AM Page 30