background image

 

6

SPECIFICATIONS 

 
DISPLAY: 

 

 

0 ... 

±

 999999, 7 segments red or green, 14.7 mm.  

 
INPUTS: 

 

 

BCD parallel, 5…24V positive or negative logic.  

 

 

 
DATA OUTPUT: 

 

RS232/RS485: 

1 Start, 1 Stop, 8 bit, no Parity.  

(250V RMS Isolation) 

 

Address: 

 

00 = RS232,   01…31 = RS485 

Baud Rate:    

300 to 19200 bd.  

Transmission: 

Continuous:  OFF, 0.1…10.0 sec.  

 

 

 

 

Request: 

any character, e.g. CRLF 

Termination:  

each telegram can be terminated with:   
nul 

 

Null 

CrLF   

Carrige Return, Line Feed 

LF 

 

Line Feed 

Cr 

 

Carrige Return 

nonE   

no character 

 
ANALOGUE OUTPUT: 

0-20mA / 4-20mA, max load 

 300 Ohm, 12 bit 

(250V RMS Isolation) 

 

0 ... ±10V or 0 ... +10V, load >10 kOhm, 12 bit 

 

 

 

 

SET POINTS: 

Four  free  programmable  Set  Points  SP1  ...  SP4  activate  four 
NPN  transistors  with  open  collector  100mA  -  60V,  or  four 
mechanical relays with open or closed contacts 5A-230VAC.  
The Set Point status is displayed with SP1…SP4 at the front. 

 
KEYBOARD:  

 

Five keys at the front: UP, DOWN, ACK, MENU, SET. 

 
MEMORY: 

 

The programmed parameters are memorized in an EEPROM. 

 
EXCITATION: 

 

5…24V/50mA adjustable, isolated. 

 
SUPPLY: 

 

 

115/230V 

±

10%, 50-60Hz, 6VA.     Option: 9-36 V DC, 4 W.  

 
CABINET: 

 

 

DIN 48x96x150mm, Panel cut-out 45x93 mm.  
Pluggable screw terminals. 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT PANEL 

 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание OC 7520

Страница 1: ..._GBM_21312 Programmable Display for BCD parallel Data Ports OC 7520 Owner s Manual ORBIT CONTROLS AG Z rcherstrasse 137 CH 8952 Schlieren Z rich Tel 41 44 730 2753 Info orbitcontrols ch www orbitcontr...

Страница 2: ...2...

Страница 3: ...BEACHTEN Dieses Ger t wurde sorgf ltig verpackt Falls es bei Ihnen in besch digtem Zustand eintrifft benachrichtigen Sie unverz glich den Orbit Controls Kundendienst Tel 41 1 730 2753 oder Fax 41 1 7...

Страница 4: ...of the instrument 9 5 1 Upper Terminals Supply 9 36VDC 9 5 2 Upper Terminals Supply 230VAC 9 5 3 BCD data inputs RS232 data outputs and Analogue Outputs 10 5 4 BCD parallel Inputs 10 5 5 Excitation s...

Страница 5: ...d from the keyboard Analog Output is an option which permits generation of 0 4 20mA or 0 10V from the BCD parallel input data shown at the display The output of 12 bits 4096 increments can be free ass...

Страница 6: ...character ANALOGUE OUTPUT 0 20mA 4 20mA max load 300 Ohm 12 bit 250V RMS Isolation 0 10V or 0 10V load 10 kOhm 12 bit SET POINTS Four free programmable Set Points SP1 SP4 activate four NPN transistors...

Страница 7: ...nt 4 ACK 003000 Select with UP DOWN and SET MENU PrESEt Display Offset 6 digits with Decimal Point and Sign ACK 000000 Select with UP DOWN and SET MENU AOUtL Display value for Analogue Output 0 4mA an...

Страница 8: ...T MENU SP3 Set Point 3 ACK 002500 Select with UP DOWN and SET MENU SP4 Set Point 4 ACK 003000 Select with UP DOWN and SET MENU PrESEt Display Offset free settable ACK 000000 Select with UP DOWN and SE...

Страница 9: ...Upper Terminals Supply 24VDC Set Points with transistor outputs 5 2 Upper Terminals Supply 230VAC Set Points with four Relays The relay and the transistor outputs can be combined The relays can be ass...

Страница 10: ...INPUT 1 800 000 2 400 000 3 200 000 4 100 000 5 80 000 6 40 000 7 20 000 8 10 000 9 8 000 10 4 000 11 2 000 12 1 000 13 800 14 400 15 200 16 100 17 80 18 40 19 20 20 10 21 8 22 4 23 2 24 1 25 SIGN 26...

Страница 11: ...11 5 5 Excitation supply for external sensors...

Страница 12: ...ransmitting Interval Menu step IntEr none Uninterrupted transmission 0 1 10 0 Seconds Hand Command from PC any letter from the PC keyboard any character or ENTER Number of digits Menu step Fn bcd POS...

Страница 13: ...990818 Supply 230VA Mode BCD parallel Input 123456 Display 123456 7 1 Test Conditions According to Norms IEC 801 4 IEC 1000 4 4 EN 50052 1 7 2 Test Set Up 7 3 Test Results Zone 1 2kV Burst Display wi...