background image

 

10

5.3 

BCD Data Inputs, RS232/485 Data Outputs and Analogue Outputs 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5.4 

BCD Parallel Inputs 

 
 
 

Pin 

INPUT 

 

Pin 

INPUT 

800 000 

400 000 

200 000 

100 000 

80 000 

40 000 

20 000 

10 000 

8 000 

10 

4 000 

11 

2 000 

12 

1 000 

13 

800 

14 

400 

15 

200 

16 

100 

17 

80 

18 

40 

19 

20 

20 

10 

21 

22 

23 

24 

25 

SIGN 

26 

SIGN 

27 

GND 

28 

GND 

29 

do not use

 

30 

do not use

 

31 

do not use

 

32 

do not use

 

33 

do not use

 

34 

do not use

 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание OC 7520

Страница 1: ..._GBM_21312 Programmable Display for BCD parallel Data Ports OC 7520 Owner s Manual ORBIT CONTROLS AG Z rcherstrasse 137 CH 8952 Schlieren Z rich Tel 41 44 730 2753 Info orbitcontrols ch www orbitcontr...

Страница 2: ...2...

Страница 3: ...BEACHTEN Dieses Ger t wurde sorgf ltig verpackt Falls es bei Ihnen in besch digtem Zustand eintrifft benachrichtigen Sie unverz glich den Orbit Controls Kundendienst Tel 41 1 730 2753 oder Fax 41 1 7...

Страница 4: ...of the instrument 9 5 1 Upper Terminals Supply 9 36VDC 9 5 2 Upper Terminals Supply 230VAC 9 5 3 BCD data inputs RS232 data outputs and Analogue Outputs 10 5 4 BCD parallel Inputs 10 5 5 Excitation s...

Страница 5: ...d from the keyboard Analog Output is an option which permits generation of 0 4 20mA or 0 10V from the BCD parallel input data shown at the display The output of 12 bits 4096 increments can be free ass...

Страница 6: ...character ANALOGUE OUTPUT 0 20mA 4 20mA max load 300 Ohm 12 bit 250V RMS Isolation 0 10V or 0 10V load 10 kOhm 12 bit SET POINTS Four free programmable Set Points SP1 SP4 activate four NPN transistors...

Страница 7: ...nt 4 ACK 003000 Select with UP DOWN and SET MENU PrESEt Display Offset 6 digits with Decimal Point and Sign ACK 000000 Select with UP DOWN and SET MENU AOUtL Display value for Analogue Output 0 4mA an...

Страница 8: ...T MENU SP3 Set Point 3 ACK 002500 Select with UP DOWN and SET MENU SP4 Set Point 4 ACK 003000 Select with UP DOWN and SET MENU PrESEt Display Offset free settable ACK 000000 Select with UP DOWN and SE...

Страница 9: ...Upper Terminals Supply 24VDC Set Points with transistor outputs 5 2 Upper Terminals Supply 230VAC Set Points with four Relays The relay and the transistor outputs can be combined The relays can be ass...

Страница 10: ...INPUT 1 800 000 2 400 000 3 200 000 4 100 000 5 80 000 6 40 000 7 20 000 8 10 000 9 8 000 10 4 000 11 2 000 12 1 000 13 800 14 400 15 200 16 100 17 80 18 40 19 20 20 10 21 8 22 4 23 2 24 1 25 SIGN 26...

Страница 11: ...11 5 5 Excitation supply for external sensors...

Страница 12: ...ransmitting Interval Menu step IntEr none Uninterrupted transmission 0 1 10 0 Seconds Hand Command from PC any letter from the PC keyboard any character or ENTER Number of digits Menu step Fn bcd POS...

Страница 13: ...990818 Supply 230VA Mode BCD parallel Input 123456 Display 123456 7 1 Test Conditions According to Norms IEC 801 4 IEC 1000 4 4 EN 50052 1 7 2 Test Set Up 7 3 Test Results Zone 1 2kV Burst Display wi...