background image

OC7520_GBM_21312 

 
 
 
 
 
 

 
 

Programmable Display for 

BCD parallel Data Ports  

 

OC 7520 

 

 
 
 
 

Owner’s Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

ORBIT CONTROLS AG 
Zürcherstrasse 137 
CH-8952 Schlieren-Zürich 
 

Tel: +41 44 730 2753 

 
[email protected] 
www.orbitcontrols.ch 

 

Содержание OC 7520

Страница 1: ..._GBM_21312 Programmable Display for BCD parallel Data Ports OC 7520 Owner s Manual ORBIT CONTROLS AG Z rcherstrasse 137 CH 8952 Schlieren Z rich Tel 41 44 730 2753 Info orbitcontrols ch www orbitcontr...

Страница 2: ...2...

Страница 3: ...BEACHTEN Dieses Ger t wurde sorgf ltig verpackt Falls es bei Ihnen in besch digtem Zustand eintrifft benachrichtigen Sie unverz glich den Orbit Controls Kundendienst Tel 41 1 730 2753 oder Fax 41 1 7...

Страница 4: ...of the instrument 9 5 1 Upper Terminals Supply 9 36VDC 9 5 2 Upper Terminals Supply 230VAC 9 5 3 BCD data inputs RS232 data outputs and Analogue Outputs 10 5 4 BCD parallel Inputs 10 5 5 Excitation s...

Страница 5: ...d from the keyboard Analog Output is an option which permits generation of 0 4 20mA or 0 10V from the BCD parallel input data shown at the display The output of 12 bits 4096 increments can be free ass...

Страница 6: ...character ANALOGUE OUTPUT 0 20mA 4 20mA max load 300 Ohm 12 bit 250V RMS Isolation 0 10V or 0 10V load 10 kOhm 12 bit SET POINTS Four free programmable Set Points SP1 SP4 activate four NPN transistors...

Страница 7: ...nt 4 ACK 003000 Select with UP DOWN and SET MENU PrESEt Display Offset 6 digits with Decimal Point and Sign ACK 000000 Select with UP DOWN and SET MENU AOUtL Display value for Analogue Output 0 4mA an...

Страница 8: ...T MENU SP3 Set Point 3 ACK 002500 Select with UP DOWN and SET MENU SP4 Set Point 4 ACK 003000 Select with UP DOWN and SET MENU PrESEt Display Offset free settable ACK 000000 Select with UP DOWN and SE...

Страница 9: ...Upper Terminals Supply 24VDC Set Points with transistor outputs 5 2 Upper Terminals Supply 230VAC Set Points with four Relays The relay and the transistor outputs can be combined The relays can be ass...

Страница 10: ...INPUT 1 800 000 2 400 000 3 200 000 4 100 000 5 80 000 6 40 000 7 20 000 8 10 000 9 8 000 10 4 000 11 2 000 12 1 000 13 800 14 400 15 200 16 100 17 80 18 40 19 20 20 10 21 8 22 4 23 2 24 1 25 SIGN 26...

Страница 11: ...11 5 5 Excitation supply for external sensors...

Страница 12: ...ransmitting Interval Menu step IntEr none Uninterrupted transmission 0 1 10 0 Seconds Hand Command from PC any letter from the PC keyboard any character or ENTER Number of digits Menu step Fn bcd POS...

Страница 13: ...990818 Supply 230VA Mode BCD parallel Input 123456 Display 123456 7 1 Test Conditions According to Norms IEC 801 4 IEC 1000 4 4 EN 50052 1 7 2 Test Set Up 7 3 Test Results Zone 1 2kV Burst Display wi...