THERMOSTAT
INSTRUCTIONS FOR USE
FIG.1 / FIG.2
19.
Mounting base
20.
Increase / Next
21.
Reduce / Back
22.
Low battery level symbol
23.
On / off icon
24.
Energy-saving temperature selection
icon
25.
Comfort temperature selection icon
26.
Programming / confirm icon
27.
Energy-saving temperature activated
symbol
28.
Comfort temperature activated symbol
29.
Room temperature
30.
Thermostat off symbol
31.
Manual functioning symbol
32.
Block touchscreen symbol
33.
Heating functioning symbol
34.
Air conditioning functioning symbol
35.
2x AA 1.5V batteries
36.
RESET button
DESCRIPTION
The VELUS TOUCH thermostat is a piece of programmable electronic equipment,
designed to manage the switching on and off of a heating or air conditioning system. It
allows three types of programmable temperatures to be assigned (Comfort temperature,
Energy-saving temperature and Antifreeze temperature).
General characteristics:
•
Large backlit touchscreen.
•
3 regulable temperature levels:
Comfort
,
Energy-saving
and Antifreeze
.
•
Regulation of temperature from +5 ºC to +35 ºC (Antifreeze from +1 ºC to +10 ºC).
•
Convenient programming, as device can be programmed outside the installation base.
INSTALLATION:
ATTENTION. The electrical devices must be installed and assembled by an authorised
installer.
BEFORE PROCEEDING TO CONNECT THE POWER SUPPLY, ENSURE THE
CABLES TO BE CONNECTED ARE NOT UNDER LIVE.
The device has internal protection against interference.
ASSEMBLY:
Electronically-controlled device for independent assembly on wall or appliance box.
We recommend the device be installed at a minimum height of 1.5 m. Assembly of the
thermostat with timer must be independent, so that it is free from obstacles and not
affected by other devices or sources of heat (sun, radiators, windows, etc.)
To install the device on the wall and to replace the batteries, it must be detached from the
mounting base, by applying pressure to the tab on the left-hand side using a flat head
screwdriver (
FIG.2
).
Mount the installation plate on the wall or appliance box using the screws included.
CONNECTION:
Remove the terminal cover using a screwdriver and connect according to the diagram in
FIG.3
.
To control an installation using contactors we recommend fitting a capacitor of suitable
value in parallel to the bobbin (0.
1 μF 275 V~).
FITTING AND REPLACEMENT OF BATTERIES:
The device is powered by 2 alkaline LR6 (AA) 1.5 V batteries (not included). Respect the
polarity indicated in the battery housing. The approximate duration of the batteries is 1
year.
When the batteries are fitted for the first time, the screen is activated and all of the display
segments come on. After a few seconds the thermostat starts to work.
When the level of the batteries in the device is low and they need replacing, the following
symbol will appear at the bottom of the screen:
So as not to lose the current settings, it is advisable to replace the batteries in under 15
seconds.
Before replacing the batteries, we recommend the thermostat be set at OFF mode.
Place the used batteries in a suitable disposal container. Respect the environment.
TOUCHSCREEN
To interact with the thermostat, all you have to do is touch one of the 6 touch icons shown
on the display with your finger (never use pens or other sharp objects). The icons
and
are multifunctional, and fulfil diverse functionalities depending on the type of pressure
applied (short or long).
BACK LIGHTING
Every time an icon on the touchscreen is pressed, the back lighting of the display is
activated to enable correct visualisation in conditions of low luminosity. The back lighting
switches off automatically 10 seconds after the last time the screen was pressed.
PROGRAMMING THE TEMPERATURE
To establish the values of the comfort and energy-saving temperatures, press the
icon
on the screen. The symbol
, will appear on the screen, and the
Set
symbol will flash
intermittently along with the comfort temperature for modification. Use the
or
icons
to increase or reduce this value. After selecting, confirm using the icon
(or confirmation
takes place automatically when 10 seconds have passed since the last time the screen
was pressed). Afterwards, the symbol
will appear on the screen, and the
Set
symbol
will flash intermittently along with the energy-saving temperature to be modified. Use the
or
icons to increase or reduce this value. After selecting, confirm using the icon
(or confirmation takes place automatically when 10 seconds have passed since the last
time the screen was pressed) and leave temperature programming.
To adjust the antifreeze temperature, see the
Advanced programming
section below.
PREDETERMINED TEMPERATURES
The predetermined factory temperatures are:
WINTER (heating)
SUMMER (air conditioning)
Comfort
: 20 ºC
Comfort
: 23 ºC
Energy-saving
: 17 ºC
Energy-saving
: 28 ºC
Antifreeze
: 5 ºC
Antifreeze
: -
To see the values of the adjusted temperatures, simply press the
or
icons.
AUTOMATIC FUNCTIONING
The thermostat will switch the heating / air conditioning on or off in accordance with the
adjusted temperature.
To activate the comfort or energy-saving temperatures, press the corresponding icon,
or
,
and the corresponding symbol will appear on the display along with the adjusted
temperature for two seconds.
When activated, the
(heating mode) or
(air conditioning mode) symbol will also be
displayed.
MANUAL FUNCTIONING
In automatic functioning mode, we can momentarily modify the value of the programmed
temperature by pressing
or
. Whilst the temperature is being modified, it will be
shown on the screen, flashing intermittently alongside the symbols
Set
and
.
After selecting, confirm with the
icon (or confirmation takes place automatically when
10 seconds have passed since the last time the screen was pressed).
ATTENTION: If the upper temperature limits (SP:HI) and / or lower temperature limits
(SP:LO) have been adjusted in the
Advanced programming
section, manual adjustment of
the temperature will be limited to that temperature range.
To exit and return to automatic functioning, press one of the temperature mode selection
icons,
or
.
OFF - FUNCTIONING
When you press
, if the appliance is on, it switches to off mode and will not switch on or
allow temperatures to be manipulated, and
appears on the screen. In this mode, the
appliance measures the room temperature but does not carry out any of its functions,
unless the temperature drops to below the programmed antifreeze temperature, in which
case the antifreeze programme will be activated, and the appliance will be switched on in
order to prevent freezing.
To exit this mode and switch the appliance on, press the
button again.
RESET
RESET to restore the default factory settings (values, temperature, programmes, etc.).
To carry out this operation, keep the
and
buttons pressed for 5 seconds at the
same time.
After a RESET, the appliance must be reprogrammed once again.
ADVANCED PROGRAMMING
With the keyboard active, keep the
key pressed for 5 seconds, and
H-C
will appear at
the top left-hand side of the screen and
“Set”
will flash intermittently on the right.
Touching the
button again enables you to modify the parameters:
•
H-C
- Functioning
“FLA”
heating in winter /
“ICE”
air conditioning in summer.
•
ANTI
– Antifreeze temperature adjustable from 1 ºC to 10 ºC.
•
DIF
- Differential adjustable from 0.1 ºC to 1 ºC.
•
SP:HI
– Upper adjustable temperature limit in Manual functioning (from 15 ºC to 35 ºC).
•
SP:LO
– Lower adjustable temperature limit in Manual functioning (from 5 ºC to 25 ºC).
•
CONT
– Adjustment of screen contrast from 1 to 5, to improve visibility of screen in
accordance with the installation height. Use
or
to select the desired value and
confirm with
or wait 10 seconds and the changes will be saved automatically.
SCREEN BLOCK
The touchscreen can be blocked to prevent undesired manipulation. To do this, press
for more than 10 seconds until the
Set
symbol flashes on the display and the letters
LOC
appear in the top left-hand part of the display. You can now enter a numeric password of
between 000 and 999, setting it digit by digit using
or
and accepting it with
.
When the touchscreen is blocked the
symbol will appear.
To unblock the touchscreen press on any icon on the screen and the
will appear, with
the flashing
Set
symbol and in the top left-hand part of the display the letters
LOC
will
appear. Now you can enter the password digit by digit using
or
and accepting with
. This enables one to make changes to the thermostat adjustments for 30 seconds,
during which the
symbol will flash. And if you wish to permanently remove the block
from the touchscreen, press
for more than 10 seconds until the
Set
symbol flashes on
the display and the letters
LOC
appear in the top left-hand part of the display. You can
then enter “---” using
and accept with
.
If you forget the password, you can unblock the appliance by removing the batteries and
using a pointed object to press inside the hole of the RESET button (
FIG.2 - 18
) beside the
battery compartment.
CLEANING THE DISPLAY
Clean with a soft, damp cloth. Do not use abrasive products or detergents.
TECHNICAL CHARACTERISTICS
Power supply:
2 alkaline LR6/AA 1.5 V batteries (not
included)
Breaking capacity:
µ 10 (3) A 250 V~
Contact:
Changeover AgNi 90/10
Duration of batteries:
Approximately 1 year
Precision of temperature measurement
±
0.5
°
C
Updating of temperature
Every 60 seconds.
Resolution
0.1
°
C.
Range of measurement on LCD:
0 ºC to 50 ºC
Type of action:
1B
Updating of output relay:
Every 60 seconds
Regulation of control temperatures:
Energy-saving
: From +5 ºC to +25 ºC
Comfort
: From +15 ºC to +35 ºC
Antifreeze
: From +1ºC to +10 ºC
Manual
: From +5 ºC to +35 ºC
Type of regulation:
ON-OFF with adjustable hysteresis of 0.1
ºC to 1 ºC (by default 0.2 ºC).
Screen block:
Activated / De-activated by Password
Regulation of display contrast:
From 1 to 5 (by default to 5)
Operating temperature:
From 0 ºC to +50 ºC
Transportation and storage temp.:
From -10 ºC to +60 ºC
Protection class:
II in correct assembly
Protection degree:
IP40 according to EN 60529 installed
correctly
Contamination situation:
2
Transient pulse voltage:
2.5 kV
Ball test temperature:
75 ºC (21.2.5); 105 ºC (21.2.6)
Connexion:
By means of screw terminals for maximum
conductor section of 2.5 mm².
WARNING:
When the charge exceeds the maximum breaking capacity current,
contactors must be used.
Subject to technical changes – additional information available at: www.orbis.es