DS 61190 IN
18
PROBLEMS AND SOLUTIONS
Problem
Cause
Solution
Light on but motor
does not work
The leaf blocked
Get rid of the blocking
The capacitor damaged
Replace capacitor
The motor jammed bearing damaged
Replace the motor
Light does not work,
motor does not work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord looses
Connect the wires as per the electric
diagram
Oil leakage
One way valve and the air ventilation
entrance are not tightly sealed
Take down the one way valve and seal
with glue
Leakage from the connection of U-
shaped section and cover
Take U-shaped section down and seal
with soap or Paint
Shake of the body
The leaf damage and causes shaking
Replace the leaf
The motor is not tightly hanged
Lock the motor tightly
The body is not tightly hanged
Fixed the body tightly
Insufficient suction
The distance between the body and the
gas top too long
Readjust the distance
Too much ventilation from open doors
or windows
Choose a new place and resemble the
machine
The Hood inclines
The fixing screws are not tight enough
Tighten the hanging screw and make
it horizontal
The hanging screw is not tight enough
Tighten the hanging screw and make
it horizontal
ELECTRICAL DIAGRAM.
MAIN PARAMETERS
Rated Input
220V-240V, 50Hz
Rated Power
234W
Lighting Power
2WX2
Motor Power
230W
Drive Mode
Single Motor
Speed
Speed I Speed II Speed III
Air tube diameter 150MM
Air output
≥
619.3m3/h
Air pressure
≥
462Pa
Noise
≤
71dB(A)