OPTIMOD-TV DIGITAL
INSTALLATION
2-17
cannot defeat the pre-emphasis in your stereo encoder, or if you will use
the analog output for monitoring, set the output Flat
.
If you are sending the analog output of the 8382 through a digital link
that uses lossy compression (like MPEG, APT-X, or Dolby), set the output
F
LAT
.
Lossy codecs cannot handle pre-emphasized signals.
If you are going to use the analog output for headphone monitoring (see
step 10 below), set the output
F
LAT
.
12.
Set digital output to be flat or pre-emphasized.
(See the notes in step 11 on page 2-16.)
A)
Press the
N
EXT
button.
B)
[Skip this step if you will not be using the digital output.]
Turn the knob to choose
P
RE
-
E
(for a 50 or 75µs pre-emphasized output),
J.17
(for a J.17 pre-emphasized output
),
P
RE
+J17
(for 50 or 75µs pre-
emphasis cascaded with J.17 pre-emphasis), or
F
LAT
(which applies 50 or
75µs de-emphasis after the processing).
Regardless of the setting of this control, the processing is always inter-
nally pre-emphasized and thus always controls peaks to follow the 50 or
75µs pre-emphasis curve.
13.
Set the digital output sample rate.
A)
Press the
N
EXT
button.
B)
[Skip this step if you will not be using the digital output.]
Turn the knob to set the Digital
O
UTPUT
S
AMPLE
R
ATE
to 32, 44.1, 48, 88.2,
or 96 kHz.
The internal sample rate converter sets the rate at the 8382’s digital out-
put. This adjustment allows you to set the output sample rate to ensure
compatibility with equipment requiring a fixed sample rate. In all cases,
the 8382’s fundamental sample rate is 32 kHz, ensuring that the output
bandwidth is always strictly limited to 16 kHz and that the processed sig-
nal can be passed through a 32 kHz uncompressed STL without addition
of overshoot.
14.
Prepare to set output levels.
A)
Press the
N
EXT
button.
You can use either program material or tone to set the output level (and
thus, the on-air modulation).
To use tone, press the
Y
ES
button.
To use program material, press the
N
O
button.
Содержание Optimod-TV 8382
Страница 22: ......
Страница 108: ......
Страница 162: ......
Страница 174: ......
Страница 213: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 25...
Страница 214: ...6 26 TECHNICAL DATA ORBAN MODEL 8382 Base Board Parts Locator Drawing for schematic 62165 000 06...
Страница 219: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 31 CPU Module...
Страница 225: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 37 RS232 BOARD PARTS LOCATOR...
Страница 227: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 39 POWER SUPPLY PARTS LOCATOR...
Страница 229: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 41 8382 I O Board Parts Locator...
Страница 234: ...6 46 TECHNICAL DATA ORBAN MODEL 8382 DSP BOARD PARTS LOCATOR DRAWING 32170 000 14...
Страница 242: ...6 54 TECHNICAL DATA ORBAN MODEL 8382 DISPLAY BOARD PARTS LOCATOR...
Страница 243: ...OPTIMOD TV DIGITAL TECHNICAL DATA 6 55 DISPLAY BOARD...
Страница 244: ...6 56 TECHNICAL DATA ORBAN MODEL 8382...