Remove a Flash Module
Caution -
Disconnect all power cables from the server prior to removing or installing a flash
module.
■
“Remove a Flash Module” on page 144
■
“Install a Flash Module” on page 146
Remove a Flash Module
1.
Prepare the server for service.
See
“Preparing the Server for Component Replacement” on page 75
.
2.
Remove the PCI mezzanine and place it on an antistatic mat.
See
“Remove the PCI Mezzanine” on page 102
.
3.
Locate the installed flash modules on the motherboard in PCIe2 slot 0.
4.
Identify the faulty flash module by pressing the Fault Remind button on the
motherboard and viewing the flash module fault and power LEDs.