Sun Datacenter InfiniBand Switch 648 Installation Guide • May 2010
0, 1, 2, 3, 4, 5, 6, 7, 8
For example, if you are installing 5 line cards, install them in slots 0, 1, 2, 3, and 4.
Note –
Where line cards slots are vacant, install line card fillers.
Related Information
■
“Install the Line Cards or Line Card Fillers” on page 72
■
“Power On the Line Cards for Installation” on page 103
■
“Fabric Card Distribution” on page 17
Line Card Handling Guidelines
Line cards use high-density XBOW connectors that interface with the midplane pins.
If these connectors are damaged, the pins of the midplane connector can also be
damaged upon line card insertion.
You must inspect the line card chassis, retainer bolts, and connectors before installing
the line card into the switch chassis.
Caution –
Lift line cards by their handles or by their sides. Do not lift line cards by
their XBOW connectors or allow the XBOW connectors to strike any object.
Related Information
■
“Fabric Card Handling Guidelines” on page 17
■
“InfiniBand Cable Cautions” on page 10
Fabric Card and Line Card Fillers
Where fabric cards and line cards are not installed, a filler must be present. The fillers
help maintain air flow characteristics so as to maintain proper chassis thermal
management.
Line card fillers are empty shells without active components. Holes in the face of a
filler permit restrictive air flow.
Содержание Sun Datacenter InfiniBand Switch 648
Страница 1: ...Sun Datacenter InfiniBand Switch 648 Installation Guide Part No 820 7738 12 May 2010 Revision A ...
Страница 8: ...viii Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 134: ...124 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 140: ...130 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...