118
Sun Datacenter InfiniBand Switch 648 Installation Guide • May 2010
3. Display and record the InfiniBand cable FRU ID information.
See
“Display the InfiniBand Cable FRU ID Information” on page 118
.
Related Information
■
Switch Administration
, component addressing
■
“Identify the Power Supply Addresses” on page 90
■
“Identify the CMC Addresses” on page 87
■
“Identify the Fabric Card Addresses” on page 99
■
“Identify the Line Card Addresses” on page 106
▼
Display the InfiniBand Cable FRU ID
Information
Note –
Retrieving FRU ID information from an InfiniBand cable is only possible if
the cable supports the IPMI specification for providing FRU ID information.
1. Identify the prerequisite and subsequent tasks you must perform in
conjunction with this procedure, to install the switch.
See the table in
“Installation Sequence” on page 20
.
2. On the CMC, type:
where:
■
IPMB_address
is from
“Identify the Line Card Addresses” on page 106
■
FRU_number
is from
“Identify the CXP Connector Addresses” on page 117
The following example is the output connector 2A on line card 1:
#
clia fruinfo
IPMB_address FRU_number
#
clia fruinfo 84 6
Pigeon Point Shelf Manager Command Line Interpreter
84: FRU # 6, FRU Info
Common Header: Format Version = 1
Board Info Area:
Version = 1
Language Code = 25
Mfg Date/Time
= Mar 13 10:34:00 2009 (6941434 minutes since 1996)
Board Manufacturer =
Board Product Name =
Содержание Sun Datacenter InfiniBand Switch 648
Страница 1: ...Sun Datacenter InfiniBand Switch 648 Installation Guide Part No 820 7738 12 May 2010 Revision A ...
Страница 8: ...viii Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 134: ...124 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...
Страница 140: ...130 Sun Datacenter InfiniBand Switch 648 Installation Guide May 2010 ...