Verify a DIMM
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
If the
show faulty
command reports a fault with a UUID, go on to
. If
show faulty
does
not
report a fault with a UUID, you are done with the verification process.
6.
Switch to the system console and use the
fmadm repair
command with the UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM
show faulty
command. For example:
#
fmadm repair 3aa7c854-9667-e176-efe5-e487e520
Related Information
■
“Understanding DIMM Configurations” on page 69
■
“Understanding DIMM Configurations” on page 69
■
“DIMM Configuration Errors” on page 72
■
“Determine Which DIMM Is Faulty (DIMM Fault LEDs)” on page 76
■
“Determine Which DIMM Is Faulty (PSH)” on page 74
■
■
86
SPARC T8-4 Server Service Manual • January 2022
Содержание SPARC T8-4
Страница 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Страница 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Страница 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Страница 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Страница 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Страница 133: ...Verify the Battery Related Information Replace the Battery on page 129 Servicing the Battery 133 ...
Страница 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Страница 149: ...Remove a Fan Module 3 Press the green button to disengage the fan module from the chassis Servicing Fan Modules 149 ...
Страница 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Страница 165: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 165 ...
Страница 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Страница 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Страница 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...