System Schematic
See
“Returning the Server to Operation” on page 191
2.
At the host prompt, determine whether the replaced FRU still shows a faulty
state.
See
.
■
If no fault is reported, you do not need to do anything else. Do not perform
the subsequent steps.
■
If a fault is reported, continue to
.
3.
Clear the fault from all persistent fault records.
In some cases, even though the fault is cleared, some persistent fault information remains
and results in erroneous fault messages at boot time. To ensure that these messages are not
displayed, type this PSH command:
faultmgmtsp>
fmadm acquit
UUID
4.
Verify the fault is cleared.
Run the
show disabled
command to see if any components are still listed as faulty. If there are
disabled components, repair the faults manually and continue to the next step to reset the server.
faultmgmtsp>
show disabled
5.
If required, reset the server.
faultmgmtsp>
exit
->
reset /System
Are you sure you want to reset /System?
y
Resetting /System ...
Related Information
■
■
System Schematic
This schematic shows the connections between and among specific components and device
slots. You can use this schematic to determine optimum locations for any optional cards or other
peripherals based on system configuration and intended use.
40
SPARC T8-4 Server Service Manual • January 2022
Содержание SPARC T8-4
Страница 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Страница 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Страница 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Страница 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Страница 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Страница 133: ...Verify the Battery Related Information Replace the Battery on page 129 Servicing the Battery 133 ...
Страница 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Страница 149: ...Remove a Fan Module 3 Press the green button to disengage the fan module from the chassis Servicing Fan Modules 149 ...
Страница 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Страница 165: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 165 ...
Страница 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Страница 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Страница 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...