Check for Faults
Related Information
■
“Interpreting LEDs” on page 27
■
Check for Faults
The
fmadm
faulty
command displays the list of faults detected by PSH. You can run this
command from either the host or through the Oracle ILOM fault management shell.
1.
Log in to Oracle ILOM.
“Log In to Oracle ILOM (Service)” on page 32
.
2.
Check for PSH-diagnosed faults.
This example shows how to check for faults through the Oracle ILOM fault management shell.
->
start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)?
y
faultmgmtsp>
fmadm
faulty
------------------- ------------------------------------ ------------- -------
Time UUID msgid Severity
------------------- ------------------------------------ ------------- -------
2014-08-27/19:46:26 4ec16c8d-5cdb-c6ca-c949-e24d3637ef27 PCIEX-8000-8R Major
Problem Status : solved
Diag Engine : [unknown]
System
Manufacturer : Oracle Corporation
Name : SPARC T8-4
Part_Number : 111+1
Serial_Number : 1238BDC0DF
----------------------------------------
Suspect 1 of 1
Fault class : fault.io.pciex.device-interr-corr
Certainty : 100%
Affects : hc:///chassis=0/motherboard=0/cpuboard=0/chip=0/hostbridge=0/
pciexrc=0
Status : faulted but still in service
FRU
Status : faulty
Location : /SYS/PM0
Detecting and Managing Faults
33
Содержание SPARC T8-4
Страница 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Страница 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Страница 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Страница 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Страница 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Страница 133: ...Verify the Battery Related Information Replace the Battery on page 129 Servicing the Battery 133 ...
Страница 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Страница 149: ...Remove a Fan Module 3 Press the green button to disengage the fan module from the chassis Servicing Fan Modules 149 ...
Страница 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Страница 165: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 165 ...
Страница 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Страница 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Страница 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...