![Oracle SPARC T8-4 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/oracle/sparc-t8-4/sparc-t8-4_service-manual_1646151032.webp)
Log In to Oracle ILOM (Service)
No.
LED
Icon or Label
Description
■
Off
– AC power might not have been connected to the power
supplies, or an SPM error has occurred and service is required.
■
Steady on
– SP is running in its normal operating state. No service
actions are required.
■
Slow Blink
– SP is initializing the Oracle ILOM firmware.
11
Overtemp LED(amber)
Indicates these conditions:
■
Off
– Indicates a steady state, no service action is required.
■
Steady on
– Indicates that a temperature failure event has been
acknowledged and a service action is required.
Log In to Oracle ILOM (Service)
1.
At the terminal prompt, type:
ssh root@
IP-address
Password:
password
Oracle (R) Integrated Lights Out Manager
Version 4.0.x rXXXXX
Copyright (c) 2017, Oracle and/or its affiliates. All rights
reserved.
->
Note -
To enable first-time login and access to Oracle ILOM, a default Administrator account
and its password are provided with the system. To build a secure environment, you must change
the default password (
changeme
) for the default Administrator account (
root
) after your initial
login to Oracle ILOM. If this default Administrator account has since been changed, contact
your system administrator for an Oracle ILOM user account with Administrator privileges.
2.
Enable the Oracle ILOM 3.0 legacy name spaces.
->
set /SP/cli legacy_targets=enabled
Note -
In Oracle ILOM 3.1, the name spaces for
/SYS
and
/STORAGE
were replaced with
/System
. You can still use the 3.0 legacy names in commands at any time, but to expose the
legacy names in the output, you must enable them. This manual uses the legacy names in the
command examples and shows the names in the output examples. For more information about
the new name spaces, see the Oracle ILOM documentation.
32
SPARC T8-4 Server Service Manual • January 2022
Содержание SPARC T8-4
Страница 1: ...SPARC T8 4 Server Service Manual Part No E80512 05 January 2022 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 4 Server Service Manual January 2022 ...
Страница 12: ...12 SPARC T8 4 Server Service Manual January 2022 ...
Страница 24: ...24 SPARC T8 4 Server Service Manual January 2022 ...
Страница 42: ...42 SPARC T8 4 Server Service Manual January 2022 ...
Страница 116: ...116 SPARC T8 4 Server Service Manual January 2022 ...
Страница 133: ...Verify the Battery Related Information Replace the Battery on page 129 Servicing the Battery 133 ...
Страница 134: ...134 SPARC T8 4 Server Service Manual January 2022 ...
Страница 149: ...Remove a Fan Module 3 Press the green button to disengage the fan module from the chassis Servicing Fan Modules 149 ...
Страница 154: ...154 SPARC T8 4 Server Service Manual January 2022 ...
Страница 165: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 165 ...
Страница 190: ...190 SPARC T8 4 Server Service Manual January 2022 ...
Страница 198: ...198 SPARC T8 4 Server Service Manual January 2022 ...
Страница 204: ...204 SPARC T8 4 Server Service Manual January 2022 ...