Servicing Fan Modules
The six fan modules in the server are located at the front of the chassis. See
. You can access the fan modules without removing the server cover.
You might need to extend the server from the rack to access the fan modules. Each fan module
is an integrated, hot-serviceable component.
These topics explain how to service faulty fan modules.
■
■
“Determine Which Fan Module Is Faulty” on page 77
■
“Remove a Fan Module” on page 77
■
“Install a Fan Module” on page 79
■
“Verify a Fan Module” on page 81
Related Information
■
“Preparing for Service” on page 45
■
“Servicing the Fan Board” on page 137
Servicing Fan Modules
75
Содержание SPARC T8-2
Страница 1: ...SPARC T8 2 Server Service Manual Part No E80511 04 June 2019 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 2 Server Service Manual June 2019 ...
Страница 12: ...12 SPARC T8 2 Server Service Manual June 2019 ...
Страница 24: ...Server Block Diagram 24 SPARC T8 2 Server Service Manual June 2019 ...
Страница 26: ...26 SPARC T8 2 Server Service Manual June 2019 ...
Страница 62: ...62 SPARC T8 2 Server Service Manual June 2019 ...
Страница 82: ...82 SPARC T8 2 Server Service Manual June 2019 ...
Страница 110: ...110 SPARC T8 2 Server Service Manual June 2019 ...
Страница 114: ...114 SPARC T8 2 Server Service Manual June 2019 ...
Страница 128: ...128 SPARC T8 2 Server Service Manual June 2019 ...
Страница 135: ...Verify the SPM Related Information Oracle ILOM documentation Install the SPM on page 131 Servicing the SPM 135 ...
Страница 136: ...136 SPARC T8 2 Server Service Manual June 2019 ...
Страница 146: ...146 SPARC T8 2 Server Service Manual June 2019 ...
Страница 164: ...164 SPARC T8 2 Server Service Manual June 2019 ...
Страница 170: ...170 SPARC T8 2 Server Service Manual June 2019 ...
Страница 176: ...176 SPARC T8 2 Server Service Manual June 2019 ...
Страница 182: ...182 SPARC T8 2 Server Service Manual June 2019 ...
Страница 188: ...188 SPARC T8 2 Server Service Manual June 2019 ...