Verify a Fan Module
6.
Return the Server to Operation
.
7.
When the server is powered, verify the new fan module. See
.
Related Information
■
“Return the Server to the Normal Operating Position” on page 158
.
■
“Remove a Fan Module” on page 71
■
“Verify a Fan Module” on page 75
Verify a Fan Module
1.
Verify that the Service Required LED on the replaced fan module is not lit.
2.
Verify that the Top Fan LED and the Service Required LED on the front of the
server are not lit.
“Front Panel Controls and LEDs” on page 28
.
Note -
If you are replacing a fan module when the server is powered down, the LEDs might
stay lit until power is restored to the server and the server can determine that the fan module is
functioning properly.
3.
Use the Oracle ILOM
show faulty
command to verify that the fault has been
cleared.
“Identify Faulted Components” on page 23
for more information on using the
show faulty
command.
Consider these two possibilities.
■
If the previous steps did not clear the fault, see
for information about the tools and methods you can use
to diagnose component faults.
■
If the previous steps indicate that no faults have been detected, then the
component has been replaced successfully. No further action is required.
Related Information
■
“Determine Which Fan Module Is Faulty” on page 71
Servicing Fan Modules
75
Содержание SPARC T8-1
Страница 1: ...SPARC T8 1 Server Service Manual Part No E80510 04 January 2022 ...
Страница 2: ......
Страница 10: ...10 SPARC T8 1 Server Service Manual January 2022 ...
Страница 20: ...20 SPARC T8 1 Server Service Manual January 2022 ...
Страница 58: ...58 SPARC T8 1 Server Service Manual January 2022 ...
Страница 106: ...106 SPARC T8 1 Server Service Manual January 2022 ...
Страница 112: ...112 SPARC T8 1 Server Service Manual January 2022 ...
Страница 128: ...128 SPARC T8 1 Server Service Manual January 2022 ...
Страница 146: ...146 SPARC T8 1 Server Service Manual January 2022 ...
Страница 152: ...152 SPARC T8 1 Server Service Manual January 2022 ...