Verify a Hard Drive
Ap_id Type Receptacle Occupant Condition
...
c2 scsi-sas connected configured unknown
c2::w5000cca00a76d1f5,0 disk-path connected configured unknown
c3 scsi-sas connected configured unknown
c3::sd2 disk-path connected unconfigured unknown
c4 scsi-sas connected configured unknown
c4::w5000cca00a59b0a9,0 disk-path connected configured unknown
...
4.
Configure the drive using the
cfgadm
-c
configure
command.
For example:
#
cfgadm -c configure c2::w5000cca00a76d1f5,0
Replace
c2::w5000cca00a76d1f5,0
with the drive name for your configuration.
5.
Verify that the blue Ready-to-Remove LED is no longer lit on the drive that you
installed.
See
6.
At the Oracle Solaris prompt, type the
cfgadm -al
command to list all drives in the
device tree, including any drives that are not configured.
#
cfgadm -al
The replacement drive is now listed as configured. For example:
Ap_id Type Receptacle Occupant Condition
...
c2 scsi-sas connected configured unknown
c2::w5000cca00a76d1f5,0 disk-path connected configured unknown
c3 scsi-sas connected configured unknown
c3::w5000cca00a772bd1,0 disk-path connected configured unknown
c4 scsi-sas connected configured unknown
c4::w5000cca00a59b0a9,0 disk-path connected configured unknown
...
7.
Perform one of the following tasks based on your verification results.
■
If the previous steps did not verify the drive, see
.
96
SPARC T7-4 Server Service Manual • May 2017
Содержание SPARC T7-4
Страница 1: ...SPARC T7 4 Server Service Manual Part No E54994 07 May 2017 ...
Страница 2: ......
Страница 10: ...10 SPARC T7 4 Server Service Manual May 2017 ...
Страница 12: ...12 SPARC T7 4 Server Service Manual May 2017 ...
Страница 86: ...86 SPARC T7 4 Server Service Manual May 2017 ...
Страница 98: ...98 SPARC T7 4 Server Service Manual May 2017 ...
Страница 110: ...110 SPARC T7 4 Server Service Manual May 2017 ...
Страница 124: ...124 SPARC T7 4 Server Service Manual May 2017 ...
Страница 141: ...Verify the Battery Related Information Replace the Battery on page 137 Servicing the Battery 141 ...
Страница 142: ...142 SPARC T7 4 Server Service Manual May 2017 ...
Страница 164: ...164 SPARC T7 4 Server Service Manual May 2017 ...
Страница 175: ...Remove a PCIe Card 2 Unlatch and open the PCIe card carrier top cover Servicing PCIe Cards 175 ...
Страница 192: ...192 SPARC T7 4 Server Service Manual May 2017 ...
Страница 200: ...200 SPARC T7 4 Server Service Manual May 2017 ...
Страница 208: ...208 SPARC T7 4 Server Service Manual May 2017 ...