Verify the Service Processor Card
114
SPARC T5-8 Server Service Manual • November 2015
b.
Download the system firmware.
Follow the firmware download instructions in the Oracle ILOM documentation.
Note -
You can load any supported system firmware version, including the firmware revision
that had been installed prior to the replacement of the service processor card.
8.
Restore the SP configuration information.
->
cd /SP/config
->
load -source
uri
target
where:
■
The acceptable values for
uri
are
tftp
,
ftp
,
sftp
,
scp
,
http
, and
https
.
■
target
is the remote location where you stored the configuration information.
For example:
->
load -source tftp://129.99.99.99/
pathname
9.
Verify the installation of the service processor card.
See
“Verify the Service Processor Card” on page 114
.
Related Information
■
“Remove the Service Processor Card” on page 110
■
“Verify the Service Processor Card” on page 114
Verify the Service Processor Card
1.
Ensure that you have completed the following:
■
Applied power to the server.
See
“Connect the Power Cords” on page 191
■
Started the system.
See
“Power On the Server (Oracle ILOM)” on page 192
2.
Verify that the SP LED on the main module or rear I/O module is lit green.
See
“Front Panel Controls and LEDs” on page 31
.
If the SP LED is lit, see
“Diagnostics Process” on page 25
.
Содержание SPARC T5-8
Страница 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Страница 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Страница 47: ...View Log Files Oracle ILOM Detecting and Managing Faults 47 View Log Files Oracle Solaris on page 46 ...
Страница 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Страница 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Страница 104: ...Install a Storage Backplane 104 SPARC T5 8 Server Service Manual November 2015 2 Lower the storage backplane into place ...
Страница 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Страница 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Страница 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Страница 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Страница 160: ...Remove a PCIe Card 160 SPARC T5 8 Server Service Manual November 2015 3 Unlatch and open the top cover of the carrier ...
Страница 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Страница 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Страница 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Страница 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Страница 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...