Install a DIMM and a Memory Riser
5.
On DIMMs that display an amber Fault LED, remove the DIMMs.
a.
Press down both DIMM slot ejector tabs as far as they will go.
b.
Carefully lift the DIMM straight up.
Caution -
Whenever you remove a memory riser or DIMM, you should replace it with another
memory riser or DIMM. Otherwise, the server might overheat due to improper airflow.
6.
Install DIMMs in the memory riser and return the memory riser to the server.
See
“Install a DIMM and a Memory Riser” on page 106
Related Information
■
“Install a DIMM and a Memory Riser” on page 106
Install a DIMM and a Memory Riser
1.
Attach an antistatic wrist wrap and unpack the DIMMs and place them on an
antistatic mat.
2.
Install the DIMMs into the memory riser by performing the following tasks.
106
SPARC T5-2 Server Service Manual • February 2017
Содержание SPARC T5-2
Страница 1: ...SPARC T5 2 Server Service Manual Part No E28856 13 February 2017 ...
Страница 2: ......
Страница 10: ...10 SPARC T5 2 Server Service Manual February 2017 ...
Страница 12: ...12 SPARC T5 2 Server Service Manual February 2017 ...
Страница 27: ...System Schematic FIGURE 2 Schematic Diagram for a 1 Processor Server Identifying Components 27 ...
Страница 52: ...52 SPARC T5 2 Server Service Manual February 2017 ...
Страница 96: ...96 SPARC T5 2 Server Service Manual February 2017 ...
Страница 112: ...112 SPARC T5 2 Server Service Manual February 2017 ...
Страница 120: ...120 SPARC T5 2 Server Service Manual February 2017 ...
Страница 140: ...140 SPARC T5 2 Server Service Manual February 2017 ...
Страница 156: ...156 SPARC T5 2 Server Service Manual February 2017 ...
Страница 162: ...162 SPARC T5 2 Server Service Manual February 2017 ...
Страница 174: ...174 SPARC T5 2 Server Service Manual February 2017 ...
Страница 180: ...180 SPARC T5 2 Server Service Manual February 2017 ...
Страница 185: ...Index SP 133 video connector location of 13 viewing message log files 50 185 ...
Страница 186: ...186 SPARC T5 2 Server Service Manual February 2017 ...