♦ ♦ ♦ C H A P T E R 6
Known Issues
This chapter provides supplementary and workaround information about the HBA. Specific bug
identification numbers are provided for service personnel.
This chapter contains the following sections:
■
“MegaRAID Storage Manager GUI-Related Issues” on page 61
■
“Utility-Related Issues” on page 62
■
“Storage-Related Issues” on page 64
MegaRAID Storage Manager GUI-Related Issues
The section contains the following information:
■
“Cannot Hotplug the HBA Card Through the MSM GUI” on page 61
■
“Cannot Assign a Global Hot Spare Through the MSM GUI” on page 62
■
“Cannot Upgrade Firmware on the HBA Therough the MSM GUI” on page 62
Cannot Hotplug the HBA Card Through the MSM
GUI
Bug 15700904
Issue:
If the MegaRAID Storage Manager (MSM) software is installed on the system, and the
MSM software services are running, you cannot perform hotplug remove and insert operations
on the HBA. When attempting to perform such an operation, a popup window is displayed
stating that the HBA card is busy and that you must close the program that is accessing the card.
Workaround:
Use the Task Manager application to stop the following MSM software services:
■
MSMFramework
Chapter 6 • Known Issues
61