Remove a PCIe Card
3.
Verify that a PCIe card is identified.
->
show /System/PCI_Devices/Add-on/Device_
x
where
x
is the slot number where the PCIe card is installed.
If a PCIe card cannot be identified, replace it. See
“Remove a PCIe Card” on page 139
.
4.
Verify that a PCIe card is faulty.
If a PCIe card is faulty, you will see
/SYS/MB/PCIE
y
under the
Value
heading:
For example:
->
show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/PCIE1
...
->
where
y
is
0
to
6
.
If a PCIe card is faulty, replace it. See
“Remove a PCIe Card” on page 139
.
If a FRU value different from
/SYS/MB/PCIE
y
is displayed, see
to identify which component is faulty.
5.
Use the Oracle ILOM
faultmgmt
shell to identify the faulty component.
.
Check the
Fault class
and
Description
fields for more information.
If a PCIe card is faulty, replace it. See
“Remove a PCIe Card” on page 139
.
6.
If you are unable to determine if a PCIe card is faulty, seek further information.
“Detecting and Managing Faults” on page 21
Related Information
■
“Remove a PCIe Card” on page 139
■
“PCIe Card Configuration” on page 138
■
“Verify a PCIe Card” on page 142
■
“Detecting and Managing Faults” on page 21
Remove a PCIe Card
Removing a PCIe card is a cold-service operation. You must power off the server before you
remove the PCIe card.
Servicing PCIe Cards
139
Содержание netra X5-2
Страница 1: ...Netra Server X5 2 Service Manual Part No E53601 03 October 2016 ...
Страница 2: ......
Страница 12: ...12 Netra Server X5 2 Service Manual October 2016 ...
Страница 20: ...20 Netra Server X5 2 Service Manual October 2016 ...
Страница 59: ...Using the Server Fault Remind Button Detecting and Managing Faults 59 ...
Страница 60: ...60 Netra Server X5 2 Service Manual October 2016 ...
Страница 123: ...Remove a Power Supply 4 Press the release tab to the left and pull on the handle Servicing Power Supplies 123 ...
Страница 128: ...128 Netra Server X5 2 Service Manual October 2016 ...
Страница 144: ...144 Netra Server X5 2 Service Manual October 2016 ...
Страница 148: ...148 Netra Server X5 2 Service Manual October 2016 ...
Страница 154: ...154 Netra Server X5 2 Service Manual October 2016 ...
Страница 180: ...180 Netra Server X5 2 Service Manual October 2016 ...
Страница 210: ...210 Netra Server X5 2 Service Manual October 2016 ...
Страница 226: ...226 Netra Server X5 2 Service Manual October 2016 ...
Страница 266: ...266 Netra Server X5 2 Service Manual October 2016 ...
Страница 274: ...274 Netra Server X5 2 Service Manual October 2016 ...