Remove a DIMM
Remove a DIMM
1.
To remove a DIMM, rotate both DIMM socket ejectors outward as far as they will
go, then carefully lift the DIMM straight up to remove it from the socket.
2.
Replace each failed DIMM with either another DIMM of the same rank size (quad-
rank, dual-rank, or single-rank) or leave the socket empty.
Related Information
■
“Understanding DIMM Layout and Population Rules” on page 160
■
Install a DIMM
1.
If you are replacing a DIMM, perform these tasks.
a.
Unpack the replacement DDR4 DIMM, and place it on an antistatic mat.
Servicing DIMMs
163