Specify Parallel Boot of the SP and Host
Specify Parallel Boot of the SP and Host
The
/SP/policy PARALLEL_BOOT
property enables the host to boot and power on in
parallel with the SP. When enabled, parallel booting occurs if an auto-power policy
(
HOST_AUTO_POWER_ON or HOST_LAST_POWER_STATE
) was on or if a user presses the power
button while the SP is in the process of booting. Oracle ILOM must be running in order to
enable the host to power on in these situations. When this property is set to
disabled
, the SP
boots first, then the host boots.
At the Oracle ILOM prompt, type:
->
set /SP/policy PARALLEL_BOOT=
value
where
value
can be:
■
enabled
– SP and host boot concurrently.
■
disabled
– SP and host boot serially.
Related Information
■
“Power On the Server (Oracle ILOM Web Interface)” on page 27
■
“Power On the Server (Oracle ILOM CLI)” on page 26
■
“Power Off the Server (Oracle ILOM Web Interface)” on page 28
■
“Power Off the Server (Oracle ILOM CLI)” on page 26
Specify Host Virtual Keyswitch Behavior
Use the
/HOST keyswitch_state
property to control the position of the virtual keyswitch.
At the Oracle ILOM prompt, type:
->
set /HOST keyswitch_state=
value
where
value
can be:
■
normal
– (Default) The server can power itself on and start the boot process.
■
standby
– Powers off the host, and disables power on.
■
diag
– Host poweron is allowed. This value overrides the settings of
/HOST/diag
target
,
resulting in Max POST being executed.
■
locked
– Host poweron is allowed, however, you are prohibited from updating flash devices
or setting
/HOST send_break_action=break
.
60
SPARC and Netra SPARC S7-2 Series Servers Administration Guide • March 2017
Содержание Netra SPARC S7-2 Series
Страница 1: ...SPARC and Netra SPARC S7 2 Series Servers Administration Guide Part No E73202 03 March 2017 ...
Страница 2: ......
Страница 10: ...10 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 24: ...24 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 54: ...54 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 56: ...56 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 62: ...62 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 68: ...68 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 81: ...Display the Locator LED State of the Server Turn Off the Locator LED on page 80 Monitoring the Server 81 ...
Страница 82: ...82 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 86: ...86 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 90: ...90 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...