Boot Mode Overview (Oracle ILOM)
ttya-mode 9600,8,n,1,- 9600,8,n,1,-
output-device virtual-console virtual-console
input-device virtual-console virtual-console
auto-boot-on-error? false false
load-base 16384 16384
auto-boot? false true
os-root-device
network-boot-arguments
boot-command boot boot
boot-file
boot-device /pci@300/pci@2/pci@0/pci ... disk net
multipath-boot? false false
boot-device-index 0 0
use-nvramrc? false false
nvramrc
error-reset-recovery boot boot
If any value in the
printenv
output is truncated, you can see the full entry by typing
printenv
followed by the variable name. For example:
{0} ok
printenv boot-device
boot-device = /pci@302/pci@2/pci@0/pci@17/LSI,sas@0/disk@p2 disk net
Related Information
■
“OpenBoot Configuration Parameters” on page 47
Boot Mode Overview (Oracle ILOM)
Boot mode (
bootmode
) properties enable you to override the default method the server uses
when it boots. This ability is useful to override particular OpenBoot or Oracle VM Server
for SPARC settings that might be incorrect, to set up OpenBoot variables using a script, or to
perform similar tasks.
For example, if the OpenBoot settings have become corrupt, you can set the
bootmode
state
property to
reset_nvram
, then reset the server to its factory default OpenBoot settings.
Service personnel might instruct you to use the
bootmode
script property for problem resolution.
The full extent of script capabilities are not documented and exist primarily for debugging.
Configuring Boot and Restart Behavior
49
Содержание Netra SPARC S7-2 Series
Страница 1: ...SPARC and Netra SPARC S7 2 Series Servers Administration Guide Part No E73202 03 March 2017 ...
Страница 2: ......
Страница 10: ...10 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 24: ...24 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 54: ...54 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 56: ...56 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 62: ...62 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 68: ...68 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 81: ...Display the Locator LED State of the Server Turn Off the Locator LED on page 80 Monitoring the Server 81 ...
Страница 82: ...82 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 86: ...86 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...
Страница 90: ...90 SPARC and Netra SPARC S7 2 Series Servers Administration Guide March 2017 ...