Storage Server Components
changes to the chassis, motherboard, fans, PCIe slots, or rear IO. This configuration uses up to 8
of the existing 24 slots in the disk cage. The chassis supports six Gen3 PCIe slots, two of which
are x16 while the remaining four are x8.
Storage Server Components
TABLE 1
Oracle Exadata Storage Server X6-2 Extreme Flash Components
Feature
Description
Processor
Two Intel E5-2630 v4, 10-core, 2.2-GHz, 85W processors.
■ Four integrated DDR4 memory controllers per processor.
Memory
Four 16-GB DIMMs per processor for a maximum of eight DDR4 DIMMs and a
maximum of 128-GB memory.
Storage
Eight 2.5-inch hot-pluggable PCIe-based NVMe SSDs.
Note -
Oracle PCIe switch controller cards are required for controlling and managing
NVMe SSDs.
PCI Express (PCIe) I/O
slots
Six PCIe Gen3 slots that accommodate low-profile PCIe cards:
■ Slots 1, 2, 5, and 6: x8 electrical interface, contain Oracle PCIe switch controller
cards.
■ Slots 3 and 4: x16 electrical interface. Slot 3 contains a dedicated InfiniBand (IB)
QDR-CX3 PCIe host channel adapter (HCA) card; slot 4 is a spare slot.
Ethernet ports
Four 10GBASE-T RJ-45 Gigabit Ethernet (10GbE) ports on the rear panel.
USB 2.0 ports
Two front, two rear, and two internal.
Note -
One internal USB port is preinstalled with a USB. The USB drive contains the
GRUB boot loader for the operating system.
Video (VGA) ports
One rear high-density DB-15 video port.
Service processor (SP)
The storage server has an integrated service processor (SP). The SP provides IPMI 2.0-
compliant remote management capabilities. The SP features:
■ Oracle Integrated Lights Out Manager (ILOM) 3.2.6.
■ Local Oracle ILOM command-line access using a serial connection.
■ Support for Ethernet access to the SP through a dedicated, 10/100/1000BASE-T
management port (NET MGT) and optionally through one of the host Ethernet ports
(sideband management).
■ Support for remote KVMS (keyboard, video, mouse, and storage) over IP.
Power supplies
Two hot-swappable and redundant 1000W power supplies.
Cooling Fans
Four 80-mm, hot-swappable fan modules. Each fan module contains two counter-
rotating fan pairs. Each power supply has its own cooling fans.
Operating system
Exadata preinstalled operating system (OS) image located on NVMe drives 0 and 1.
10
Oracle Exadata Storage Server X6-2 Extreme Flash Installation Guide • July 2018
Содержание EXADATA X6-2
Страница 1: ...Oracle Exadata Storage Server X6 2 Extreme Flash Installation Guide Part No E63688 03 July 2018 ...
Страница 2: ......
Страница 8: ...8 Oracle Exadata Storage Server X6 2 Extreme Flash Installation Guide July 2018 ...
Страница 14: ...14 Oracle Exadata Storage Server X6 2 Extreme Flash Installation Guide July 2018 ...
Страница 24: ...24 Oracle Exadata Storage Server X6 2 Extreme Flash Installation Guide July 2018 ...
Страница 60: ...60 Oracle Exadata Storage Server X6 2 Extreme Flash Installation Guide July 2018 ...
Страница 66: ...66 Oracle Exadata Storage Server X6 2 Extreme Flash Installation Guide July 2018 ...
Страница 70: ...70 Oracle Exadata Storage Server X6 2 Extreme Flash Installation Guide July 2018 ...