Install the Internal HBA Card in PCIe Slot 4
Servicing FRUs
145
6.
Lift the super capacitor up to release the reclosable fasteners that secure it to
the server's chassis [2].
7.
Disconnect the super capacitor cable from the super capacitor and place the
super capacitor on an antistatic mat [2].
8.
Carefully slide the SAS cables and super capacitor cable through the chassis
mid-wall and remove the cables from the server.
For instructions, see
“Remove the Internal HBA SAS Cable Assembly” on page 173
Install the Internal HBA Card in PCIe Slot 4
1.
Unpack the replacement host bus adapter (HBA) card, the super capacitor, the
SAS cables, and the super capacitor cable, and retrieve the PCIe riser for slot 3.