EN 31
FILTER VERSION
One active charcoal filter is needed for this and can be obtained from your usual retailer.
The filter removes the grease and smells from the extracted air before sending it back into the room
through the upper outlet grid.
INSTALLATION
The minimum distance between the supporting surface for the cooking equipment on the hob and the
lowest part of the range hood must be not less than 50cm from electric cookers and 65cm from gas or
mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If
provided with a plug connect the hood to a socket in compliance with current regulations and positioned
in an accessible area, after installation. If it not fitted with a plug (direct mains connection) or if the plug
is not located in an accessible area, after installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the mains under conditions relating to over-
current category III, in accordance with installation instructions.
Warning!
Before re-connecting the hood circuit to the mains supply and checking the efficient function,
always check that the mains cable is correctly assembled.
The hood is provided with a special power cable ; if the cable is damaged, request a new one from
Technical Service.
MOUNTING
Very heavy product; hood handling and installation must be carried out by at least two persons. Before
beginning installation:
•
Check that the product purchased is of a suitable size for the chosen installation area.
•
Remove the charcoal (*) filter/s if supplied (see also relative paragraph). This/these is/are to be
mounted only if you want lo use the hood in the filtering version.
•
Check (for transport reasons) that there is no other supplied material inside the hood (e.g. packets
with screws (*), guarantees (*), etc.), eventually removing them and keeping them.
•
If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide
easier access to rear wall/ceiling. Otherwise put a thick, protective covering over countertop,
cooktop or range to protect from damage and debris. Select a flat surface for assembling the unit.
Cover that surface with a protective covering and place all canopy hood parts and hardware in it.
•
In addition check whether near the installation area of the hood (in the area accessible also with the
hood mounted) an electric socket is available and it is possible to connect a fumes discharge device
to the outside (only suction version).
•
Carry out all the masonry work necessary (e.g. installation of an electric socket and/or a hole for the
passage of the discharge tube).
Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified
technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/
ceiling must be strong enough to take the weight of the hood. Do not tile, grout or silicone this appliance
to the wall. Surface mounting only.
Содержание gorenje S1 BHP643ORAB
Страница 1: ...S1 BHP643ORAB S1 BHP643ORAW DETAILED INSTRUCTIONS FOR USE OF THE KITCHEN HOOD...
Страница 4: ...1 2 A 100 160 16 cm 10 cm 16 cm 1 cm 7 11 9 8 12a 10...
Страница 5: ...4x 3 9x9 5mm min 10 max 50 13a 12b 14a 13b 14b 15b...
Страница 6: ...4 szt 1 16b 18 17 19 4 20 21...
Страница 7: ...LED JDR GU10 3W LED JDR GU10 3W 22 23...
Страница 8: ...BG 8 BG...
Страница 10: ...BG 10 50cm 65cm G G...
Страница 12: ...BG 12 ON OFF T7 T8 3 T8 5 T8 5 T7 T8 T7 6 16 mm T8 T7 26 ON OFF T3 5 T3 5 T3 5 T6 T7 T8 16 mm 26 mm...
Страница 13: ...BG 13 10 90...
Страница 49: ...GE 49 GE...
Страница 51: ...GE 51 50 65 III...
Страница 53: ...GE 53 3 ON OFF T7 T8 3 T8 5 T8 5 ON OFF T3 5 1 3 5 3 5...
Страница 54: ...GE 54 LED LED 10 90...
Страница 65: ...KK KK 65 KK 2012 19 WEEE...
Страница 67: ...KK 67 50cm 65cm 3 5 15...
Страница 69: ...KK 69 ON OFF T3 5 1 T3 5 T3 5 4 10 90...
Страница 80: ...MK MK 80 MK 2012 19 EC Waste Electrical and Electronic Equipment WEEE...
Страница 82: ...MK 82 50cm 65cm III...
Страница 84: ...MK 84 T7 T8 T7 T6 16 T8 T7 26 ON OFF T3 5 1 T3 5 T3 5 4 LED LED 10 90 T6 T7 T8 16 mm 26 mm...
Страница 95: ...RU 95 RU...
Страница 97: ...RU 97 50cm 65cm 3...
Страница 99: ...RU 99 T7 T8 3 T8 5 T8 5 T7 T8 T7 T6 16 T8 T7 26 T3 5 1 T3 5 T3 5 4 T6 T7 T8 16 mm 26 mm...
Страница 100: ...RU 100 LED 10 90 720 16 06 97 10...
Страница 121: ...121 ON T8 3 T8 T7 OFF 5 5 T8 T8 T7 T7 26 T8 T6 16 T7 5 T3 OFF ON T3 5 5 T3 LED 10 LED 90 T6 T7 T8 16 mm 26 mm...
Страница 123: ...123 EN 55014 1 CISPR 14 1 EN 55014 2 CISPR 14 2 EN IEC 61000 3 2 EN IEC 61000 3 3 EMC EM ON boost 10 90 50 65...
Страница 125: ......
Страница 126: ......
Страница 127: ......