UMX-03/0 version 4.3.000.5
6
Modular audio matrix
with IP connection
UMX-03/0
3.1.
Power and control module
1)
Connector ETH A
Is used to connect the unit to the IP network.
(1a)
SPEED indicator
(yellow LED):
Speed of the network. Indicates a speed of 100 Mbps
when illuminated. The light extinguished indicates a
network speed of 10 Mbps (it is highly recommended to
use a transmission speed of 100 Mbps).
(1b)
LINK/ACTIVITY indicator
(green LED):
When illuminated it indicates a network connection.
When flashing it indicates that data is being sent or
received.
2)
Connector ETH B
Is used in a redundant network as a secondary connection to
the IP network.
3)
BUS
CAN Contacts
Data communication bus
between the UMX-03/0
matrix, the UMX-03/0E
slave and CAN peripherals.
To connect see figures 4
and 12.
4)
FAIL Contacts
Fail relay. Switches when a system alarm is detected.
Maximum DC charge current: 150 mA
Maximum DC or AC peak charge voltage: 350 V
5)
GND Contact
6)
INPUT Contacts CT 1, 2, 3 and 3
Input contacts. The functionality and de-energized state (NC/NO) are configured through the configuration software. They may
be configured as general purpose contacts or in the evacuation system as emergency mode activation contacts, evacuation
message activated...
If you wish, the system may monitor these contacts (short-circuit or open line detection).
To connect follow figure 5. If you wish to monitor the contact, follow figure 6.
Figure 3
Figure 5
INPUT CONTACT CONNECTION
WITHOUT MONITORING
Figure 6
INPUT CONTACT CONNECTION
WITH MONITORING
Figure 4