Modular audio matrix
with IP connection
UMX-03/0
COMPONENT
GENERATING
THE ALARM
TYPE OF ALARM
DESCRIPTION
RECOVERY
C ["n":"p" ]
(n= Number of
slave, id.)
If the value is 0,
the unit is a
UMX-03/0)
(p= Slot occupied
by the card)
CONFIGURATION
ERROR
The unit "n" incorporates a card in slot
"p" that does not appear in the
configurations of the installation.
Use the
P.A. Manager
software to add
the unit to the installation tree.
or
remove the card from the UMX-03/0 or
UMX-03/0E chassis
"ZONE NAME"
LZ LINE ERROR
When monitoring the speaker line of
the indicated zone, the system detects a
low impedance error.
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
"ZONE NAME"
HZ LINE ERROR
When monitoring the speaker line of
the indicated zone, the system detects a
high impedance error.
The impedance in the speaker line has
changed. Inspect said line and check the
status of the speakers.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
"ZONE NAME"
AMPLIFIER
ERROR
Zone amplification error
Check the operation of the amplifier
"ZONE NAME"
SHORT LINE
ERROR
When monitoring the speaker line of
the indicated zone, the system detects a
short-circuit in the line.
Inspect that speaker line.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
"ZONE NAME"
OPEN LINE
ERROR
When monitoring the speaker line of
the indicated zone, the system detects
an open line error.
Inspect that speaker line.
If the status of the line is correct, you
can adjust the monitoring of the line
and expand the tolerance margin for
detecting the error.
•
Acoustic alarm indicator (buzzer):
Acoustic indication that is generated by the unit when it receives an alarm. The acoustic
indication is a buzzing sound that lasts 10 seconds is periodically repeated every 20 seconds.
This acoustic indication may be activated or deactivated through the configuration software.
If the acoustic indication is activated, it sounds each time an alarm is received.
The alarms may be silenced. To accomplish this:
1.
Display the alarms tab via the
or
keys.
2.
Use the navigation keys
/
to view one of the alarms and press
OK
.
3.
Using the
/
keys, select the
MUTE BUZZER
option.
4.
Press
OK
.