Be careful that flue pipe does not enter into the free section of the chimney.
Maintain the correct distances specified by building regulations between the flue pipe and
combustible material.
This appliance must never be connected to a shared flue system.
If the chimney pressure is too low or too high this may cause problems with the working of
the stove.
3.2. Safety rules
During the installation of the stove, all the building regulation and safety requirements
must be complied with, with particular reference to the recommendations of Approved
Document J.
The appliance must be installed on a floor with an adequate load-bearing capacity. If an
existing construction doesn't meet these prerequisites then suitable measures (e.g. a load
distribution plate) shall be taken to achieve it.
Pay attention to minimum distance required from combustible materials.
A wooden mantelpiece should not be used above an insert stove.
3.3 Minimum distances to combustibles
A
1600mm
In the area of thermal radiation
B1
200mm
Back space between the wall and stove
B2
500mm
Side space between combustible wall and stove
6
Содержание Tempo 100
Страница 1: ...OPERATION AND INSTALLATION MANUAL OPUS TEMPO...
Страница 2: ...FIRED BY DESIGN 1...