D
GB
NL
F
I
P
21
Function test
Nach Anschluss der Spannungsversorgung beträgt die
Aufwärmzeit 60 sek. Anschließend blinkt die interne
LED und die angeschlossenen Verbraucher werden
eingeschaltet. Der Bewegungsmelder ist betriebsbereit,
wenn LED und Verbraucher erlöschen.
The function test
serves to test the motion sensor for proper detection
function in the desired installation location.
In order to perform the function test, set the arrow
8
to
the “test” position.
To do this, make the following settings:
Set the sliding switch
6
to AUTO.
Turn the METER adjustment screw
9
to the “+” position.
Turn the TIME adjustment screw
8
to the “test” position.
The twilight detection is deactivated.
Correctly install the motion sensor and connect it to the
mains voltage
4
5
.
Begin the function test
11
from outside of the probable
detection range and pass through the detection range
transversally until the motion sensor switches.
The LED
10
and the connected consumer switch for
2 seconds.
Adjust the “METER” adjustment screw
9
until the
desired detection range is set.
Repeat the function test
11
until a satisfactory result is
achieved.
LED
11
10
Start
Finish
Manual ON (button activation)
For this, connect one or more buttons to the normally
open contact on the T
5
terminal of the motion sensor.
Press the button (normally open contact) and switch
the motion sensor ON (regardless of the set twilight
threshold). The motion detector switches off again in
accordance with the set duty cycle.
Содержание BWM 180
Страница 1: ...Bedienungsanleitung BWM 180 D GB NL F I...