2.4 Advice and safety

Most of defective loop installations are the result of

a lack of preparation. Take your time before starting

your installation and always keep this manual in an

accessible place.

Ideally, the loop amplifier should be placed under a

desk or counter and the loop installed as shown in

the illustration below. The amplifier should be

installed in an area not accessible to children or

unauthorised personnel. When choosing the location

of the loop, take into account the possible future

installation of other equipment. Place the system at

the point of contact the most frequently used by

customers/visitors.

To prevent accidents or personal injury caused by

electrical shocks, never place any type of

container filled with a liquid, such as a vase, on or

around the device.

Never pull on the power cord to remove the plug

from the wall outlet; always pull the plug.

Do not operate the device near heat sources or in

rooms

with

high

humidity.

(Operating

temperature range 0-45°C).

Depending on the stress it is exposed to, the

device can develop high temperatures. Be careful

not to touch these elements - risk of burns!

An installation must be carried out by qualified

personnel.

The device must be out of reach of unauthorized

persons.

The device may only be operated by trained

staff qualified for loop installation.

The device is intended to be used for inductive

loop systems only.

To prevent potential injury, do not position

this device higher than 2 meters from the

ground

Connect the loop driver only to wiring which

complies to IEC-60364.

THE

AMPLIFIER

MUST

BE

EARTHED

/GROUNDED

Refer all servicing to a qualified staff. Servicing

is required when the device has been damaged

in any way, such as a power supply cord or

plug is damaged, liquid has been spilled or

objects have fallen into the device, if it have

been exposed to any rain or moisture, does

not operate normally or has been dropped

TO PREVENT ELECTRIC SHOCK DO NOT

REMOVE THE COVER. THERE ARE NO USER

SERVICEABLE PARTS INSIDE. REFER SERVICING

TO QUALIFIED STAFF

Содержание DCL20-65

Страница 1: ...Kit DCL20 65 EN FR Manuel d installation et d utilisation DCL20 65 Installation and usermanual DCL20 65 Amplificateur de boucle inductionmagn tique pour interphone Hearing loop amplifier for intercom...

Страница 2: ...2 DCL20 65 Manuel d installation et d utilisation Installation and user manual...

Страница 3: ...Amplificateur de boucle inductionmagn tique pour interphone FR Manuel d installation etd utilisation DCL20 65 Fran ais Kit DCL20 65...

Страница 4: ...ion 8 3 1 Composition et montage de la boucle 8 3 2 Installation de la boucle dans le comptoir 8 4 Connexions et r glages 10 4 1 Connexion audio 10 4 2 Connexion de la boucle et de l alimentation 10 5...

Страница 5: ...e alerte de type avertissement peut entra ner des dommages mat riels et corporels graves Danger La non observance d une alerte du typedanger peut entra ner la mort 1 4Ic nes 1 4 1 Ic nes etnotes Les i...

Страница 6: ...Lecontenu Ce kit comprend Un amplificateur DCL20 Une alimentation 12V 1 5A Un c ble boucle de1 80m adaptateur Clips autocollants Un cordon de liaison Un c ble audio Lot de 3 autocollants Espace adapt...

Страница 7: ...alimentation pour d brancher la prise tirer toujours sur la prise elle m me Ne pas utiliser le syst me dans un environnement humide ou proximit d une forte source de chaleur restez entre 0 45 C Ne tou...

Страница 8: ...t cr e etconnect e 3 2 Installation de la boucle sous le comptoir Il existe plusieurs possibilit s de placement d une boucle sur un comptoir comme d crit ci apr s N anmoins la premi re version d crite...

Страница 9: ...allique et ne permettrait pas d quiper le comptoir convenablement Il existe d autres so lutions pour l installation d une boucle dans un comptoir m tallique voir figure 3 Pour une plus grande couvertu...

Страница 10: ...Bornier Type d entr e Ligne ou micro connexion vis Entr e 2 Type Bornier Type d entr e Ligne basse imp dance 100V avec un adaptateur 4 2 Connexion de la boucle et de l alimentation Connectez le c ble...

Страница 11: ...oucle peut tre install e au niveau du sol ou du plafond plus pr cis ment entre 1 10m et 2 20m de la hauteur d coute oreilles La pr sence d une boucle auditive est souvent signal e par un logo bleu rep...

Страница 12: ...voyer l appareil dans son emballage d origine conserver pendant l int gralit de la p riode de garantie Cette garantie ne s applique pas pour les dommages occasionn s par une mauvaise manipulation ou e...

Страница 13: ...ucle 0 5 Ohm 1 Ohm Courant de cr te 4A Courant RMS 2A 1 KHz Protection Thermique court circuitet d marrage Dimensions et poids en mm DCL20 92 x 52 x 18 L x H xP Emballage 190 x 190 x 50 Poids 0 350g D...

Страница 14: ...14 DCL20 65 Manuel d installation et d utilisation Installation and user manual...

Страница 15: ...Installation and usermanual DCL20 65 EN Hearing loopamplifier for intercom Kit DCL20 65 English...

Страница 16: ...on 21 3 1 Composition and assembly of the loop 21 3 2 Installation of the loop in the counter 21 4 Connections and settings 23 4 1 Audio connection 23 4 2 Loop and power connection 23 5 Working princi...

Страница 17: ...n compliance with a type alert Warning may result in serious personal injury and property damage Danger Failure to observe a danger alert may resultin death 1 4Icons 1 4 1 Icons andnotes Icons used wi...

Страница 18: ...ion Table 2 Mass unitsconversion Table 3 Pressure unitsconversion Table 4 temperature unitsconversion 25 40 mm 25 4 mm 1 mm 1 00000 25 40 mm 2 54 cm 1 cm 0 3937 po 30 48 cm 0 3048 m 1 m 3 281 pd 1 ml...

Страница 19: ...m2 up to 2000m2 2 2 Contents This kit includes A DCL20 amplifier A power supply A 1 80m loop cable and adaptor One link cable One audio cable Adhesive clips A set of 3 stickers space adaptedfor hearin...

Страница 20: ...lug Do not operate the device near heat sources or in rooms with high humidity Operating temperature range 0 45 C Depending on the stress it is exposed to the device can develop high temperatures Be c...

Страница 21: ...block of the am plifier Your loop is now created andconnected 3 2 Installation of the loop in the coun ter 1 There are several possibilities to install a loop in a counter as described below however...

Страница 22: ...field would be absorbed by the metal mass and would leading to unproper audio coverage There are other solutions to install a loop on a metallic counter see figure 3 For greater coverage around the c...

Страница 23: ...rminal Block Input type Line or microphone screwconnec tion Input 2 Type Terminal Block Input type Line low impedance 100V withan adapter 4 2 Loop and powerconnection Connect the loop cable to the Loo...

Страница 24: ...or at the roof level more precisely between 1 10m and 2 20m from the listening height ears The presence of an hearing loop is often indi cated by a blue logo representing a crossed out ear and a lett...

Страница 25: ...r s warranty This warranty covers the repair of the product and returning it to you free of charge It is recommended that you send in the product in its original packaging so keep the packaging for th...

Страница 26: ...nce 0 5 Ohm 1 Ohm Peak current 4A Current RMS 2A 1 KHz Protection Thermal short circuitand start Dimensions andweight in mm DCL20 92 x 52 x 18 L x H xP Packaging 190 x 190 x50 Weight 0 350g DCL20 65 M...

Страница 27: ...27 DCL20 65 Manuel d installation et d utilisation Installation and user manual...

Страница 28: ...28 Notes DCL20 65 Manuel d installation et d utilisation Installation and user manual...

Страница 29: ...DCL20 65 Manuel d installation et d utilisation Installation and user manual 29 Notes...

Страница 30: ...2021 05 Manuel d installation et d utilisation Installation and user manual DCL20 65 Pour toutes questions complementaires contactez nous For any questions contactus OPUS TECHNOLOGIES ZI LAGRANGE II...

Отзывы: