Start of operation (Network / IP Address configuration) 

 

1.  Please connect the camera power supply to the power connector of 

the  CR  camera  and  then  connect  the  power  supply  to  the  110-
240 Volt power source. The camera will operate after switch on the 
power switch on the camera backside (I..0) to position (I).   

Make sure, that your PC has a Gigabit Ethernet (GigE) interface. To 
operate the CamRecord-Sprinter cameras, please set both camera 
and PC network adapter on the same subnetwork: 

 

 

Please note, that the IP Address may either be changed in the Personal 
Computer (Network card) or in the camera or both. 

To set the IP Address in the Personal Computer please ask your System 
Administrator. 

To set the IP Address of the camera please use an USB2 Stick formatted 
to 

FAT32

 and use the Optronis tool IPConfiguration: 

1) 

Star

t IPConfiguration tool “IPConfiguration.exe” to create a text 

file IP.CFG 

2) 

Copy IP.CFG to the USB2 Stick  

3) 

Power  off  the  camera  and  plug  the  USB2  Stick  into  the  CR-
S3500 camera 

4) 

Power on the camera and wait, until boot time has finished (see 
led states detailed later in the document). 

5) 

USB2 Stick can be removed once the boot is finished. 

 

Alternatively 

1) 

Create a text file on the USB2 Stick named: IP.CFG 

2) 

Open  the  text  file  and  write  2  lines.  First  Line  is  the  IP  of  the 
camera (e.g. 192.168.100.254), second line is the Subnet mask 
(e.g. 255.255.255.0) 

3) 

Save the file, plug it to the camera, power on the camera and 
wait until the camera has booted.  

4) 

After boot, the camera has accepted the new IP address.  

 

Alternatively  

1) 

Plug an empty USB2 Stick to the camera 

Содержание CR-S3500

Страница 1: ...CamRecord CR S3500 User Manual Ref 1900 SU 02 C...

Страница 2: ...Viewer version http optronis com en products camrecord cr s3500 mc Support We hope that this manual can answer your questions but should you have any further questions or if you wish to claim a servic...

Страница 3: ...ess configuration 14 Camera 17 Lens Interface 17 Camera Socket 17 Electrical Interface 18 Camera detailed view 18 SSD Slot 18 Power Switch 18 Programmable Output PO 19 Synchronization Output SO 19 Fir...

Страница 4: ...sor 26 Performance Examples 28 CR S3500 28 Mechanical Dimensions 29 CR Series FM FMG 29 External Inputs 31 Trigger Synchronization input 31 Synchronization Timing 31 Trigger Timing 31 External Outputs...

Страница 5: ...D and its holding system 22 Figure 15 Trigger Input schematic presentation 23 Figure 16 Synchronization Input schematic presentation 23 Figure 17 High impedance termination 24 Figure 18 50 Ohm termina...

Страница 6: ...S3500 Ref 1900 SU 02 C Page 4 Revision Manual revision Date Comments 1900 SU 02 C 28 09 2017 Update content 1900 SU 02 B 29 03 2017 Update layout Add Firmware update paragraph 1900 SU 02 A 28 02 2017...

Страница 7: ...e responsibility that the following apparatus Product CR S3500 Conforms with the essential requirements of the EMC Directive 2014 30 EU based on the following applied specifications Specifications EN...

Страница 8: ...on 1830 SS 10 M Monochrome sensor 16GB 16 GByte Memory 256GB_SSD 256GByte SSD for Backup 512GB_SSD 512GByte SSD for Backup Lens mount CM CMount FM FMount FMG FMount and Nikon G Lenses Power supply 12V...

Страница 9: ...ase and water Make sure that all the connecting cables are in good condition and that they are well mounted to their sockets Please use the socket of the camera and connect it to a sufficiently stable...

Страница 10: ...02 C Page 8 Typical System Configuration Figure 1 Typical System Configuration with Personal Computer PC Power Supply CamRecord Sprinter PC with GigE Interface 100 240 VAC 50 60 Hz CamRecord PC Softw...

Страница 11: ...ef 1900 SU 02 C Page 9 Figure 2 Typical System Configuration with Android Tablet Power Supply CamRecord Sprinter 100 240 VAC 50 60 Hz CamRecord Android App TimeViewer USB2 WI FI dongle Android tablet...

Страница 12: ...ns To connect properly the lens to the lens holder first put the lens reference in front of the lens holder reference Then turn the lens anti clockwise until the silver clip silver button on the lens...

Страница 13: ...lens please pull back first the silver clip button back in order to unlock the lens Then the silver clip has still to be pulled back the lens has to be turned clockwise until the lens is unmounted co...

Страница 14: ...ed continuously When mounting a standard F Mount lens with mechanical aperture ring onto the FMG adapter please pay attention that the aperture ring on the adapter don t affects the aperture adjustmen...

Страница 15: ...s To unmount the lens please pull back first the silver clip back in order to unlock the lens Then the silver clip has still to be pulled back the lens has to be turned clockwise until the lens is unm...

Страница 16: ...tem Administrator To set the IP Address of the camera please use an USB2 Stick formatted to FAT32 and use the Optronis tool IPConfiguration 1 Start IPConfiguration tool IPConfiguration exe to create a...

Страница 17: ...inished 6 USB2 Stick can be removed once the boot is finished 2 After setting camera and PC on the same subnetwork the software package TimeViewer can be installed 3 When network is configured and sof...

Страница 18: ...s to re activate or disactivate this searching function To reach Option menu please click on Extra button in the top left corner of the main window To verify the operation of the camera the following...

Страница 19: ...FMG Other lens interfaces as e g CS Mount and metrical formats can be chosen Please contact Optronis GmbH Accessories Macro and magnification applications may need special distance washers between len...

Страница 20: ...onnector 11 IRIG B Input 6 HDMI Connector local view 12 Serial Number Figure 13 CamRecord Sprinter camera electrical interface SSD Slot 1 SSD hard disk slot for non volatile backup of the image sequen...

Страница 21: ...firmware update USB2 stick HDMI Connector 6 The cameras show live images on the HDMI Connector during Live Mode and during Recording Mode This allows to optimize operating conditions of the applicatio...

Страница 22: ...se refer to the TimeViewer software package to activate the synchronization input LED A LED B 10 Color code Led color O Orange G Green R Red State Timing Off 0 On SO Solid 100 On SF Slow Flash 0 5Hz 1...

Страница 23: ...rom DDR not live G SF No SSD connected O SO SSD detected but not formatted O SF SSD RDY G SO SSD Saving sequence WR SSD G FF G FF SSD replay RD SSD G SF G SO SSD Full no more backup possible but repla...

Страница 24: ...docking station connected to a PC to readout image data with the TimeViewer software Figure 14 SSD and its holding system Mount SSD To mount the SSD please switch off the power of the camera put the...

Страница 25: ...is rising edge sensitive External Switch Allows to use an external switch a TTL signal or an open collector to trigger the sequence The trigger signal is falling edge sensitive which means that e g t...

Страница 26: ...ous to the frame rate of the camera The positive edge is synchronous to the beginning of the exposure time of each frame Output Impedance 50 Ohm Signal Level approx 4 Volt into high impedance 500Ohm a...

Страница 27: ...nfiguration TimeViewer Software Windows 7 8 10 32 or 64bits Large Hard disk e g 1 TBytes Performant Processor and Graphics card For optimum performance and best display on the monitor we recommend to...

Страница 28: ...t full resolution 17 54 x 11 78 mm Frame Diagonal at full resolution 21 130 mm Sensor dynamics 48 dB electrical 8Bit Ambient Temperature 0 C 40 C Humidity 80 relative non condensed Weight 1300 g witho...

Страница 29: ...CamRecord CR S3500 Ref 1900 SU 02 C Page 27 Figure 19 Spectral Response Curve...

Страница 30: ...ormance Examples CR S3500 Speed Resolution h x v Video Memory 16GB Recording Time max Speed Exposure Time max Speed 50 3500 Images s 1280 x 860 4 1 s 2 s 285 s 50 4200 Images s 1280 x 720 4 1 s 2 s 23...

Страница 31: ...CamRecord CR S3500 Ref 1900 SU 02 C Page 29 Mechanical Dimensions CR Series FM FMG Figure 20 Bottom view Figure 21 Side view...

Страница 32: ...CamRecord CR S3500 Ref 1900 SU 02 C Page 30 Figure 22 Top view Figure 23 Front view...

Страница 33: ...Rising TTL Falling Trigger on external switch or Open Collector Rise Time 100 nsec Input Impedance high 800 Ohm Synchronization Timing Figure 24 Input synchronization timing CR S3500 Delay T 3 27 sec...

Страница 34: ...50 Ohm max reverse Protection 10 Volt Edge Positive Rise Time 50 nsec Synchronization Timing Figure 26 Output synchronization timing CR S3500 T 100 nsec Te 100 nsec Tt min 0 T Delay between the begin...

Страница 35: ...s camrecord cr s3500 mc Alternatively you can check TimeViewer installation folder Firmware and use its cr_server and rbf files Why updating camera firmwares When updating TimeViewer control software...

Страница 36: ...tted to FAT32 and use the Optronis tool CR1900_FlashTool Step 1 Copy new files on USB sticks Start CR1900_FlashTool Select HW and SW files and USB stick path see Figure 28 Click on copy button see Fig...

Страница 37: ...CamRecord CR S3500 Ref 1900 SU 02 C Page 35 Figure 28 Select files and path Figure 29 Copy files to USB stick Figure 30 Connected to camera Figure 31 HW Update progressing 1 2...

Страница 38: ...CamRecord CR S3500 Ref 1900 SU 02 C Page 36 Figure 32 HW Update progressing 2 2 Figure 33 Update finished Figure 34 New HW is loaded at next power cycle...

Отзывы: