CP80-25-M/C-72
Ref. 1889-SU-01-D
Page 36
Access : RW
FlashSaveWithAutoStart
This feature saves the current configuration into flash. After reboot, the camera
loads the saved configuration and starts the acquisition automatically.
FlashSaveWithoutAutoStart
This feature saves the current configuration into flash. After reboot, the camera
loads the saved configuration without starting the acquisition automatically.
DisableFlashLoad
This feature disables the flash configuration load at the camera boot.
IndicatorLamps
Switch ON/OFF indicator lamps.
Write 0x00 to switch ON the indicator lamps.
Write 0x01 to switch OFF the indicator lamps.
Address : 0x601C
Length : 4
Mask : 0x00FF0000
Access : RW
ColorSensor
Has camera a color sensor.
Return 0x1 for a color sensor and 0x0 for a monochrom sensor
Address : 0x6038
Length : 4
Access : RO
Gen<i>Cam
Optronis ships together with the CP80-25-M/C-72 camera a XML file that is
Gen<i>Cam compatible. The XML file follows the SNFC (Standard Features
Naming Convention).
Please ask, if needed, the Optronis customer service for the availability of this
XML file.