58
He blackened the peak of a sensitive mercury thermometer. This thermometer, a glass prism that led sun
rays onto a table made his measuring arrangement. With this, he tested the heating of different colors of
the spectrum. Slowly moving the peak of the blackened thermometer through the colors of the spectrum,
he noticed the increasing temperature from violet to red. The temperature rose even more in the area
behind the red end of the spectrum. Finally he found the maximum temperature far behind the red area.
Nowadays this area is called “infrared wavelength area”.
Figure 29:
The electromagnetic spectrum and the area used for temperature measurement
For the measurement of “thermal radiation” infrared thermometry uses a wave-length ranging between
1 µ and 20 µm. The intensity of the emitted radiation depends on the material. This material contingent
constant is described with the help of the emissivity which is a known value for most materials
(see enclosed table emissivity).
Содержание PI 160
Страница 1: ...Operator s Manual optris PI 160 200 230 400 450 450G7 640 1M Infrared camera...
Страница 6: ...6 Appendix F Wiring diagrams PIF 79 Appendix G CE Conformity 83...
Страница 25: ...25 Technical Data Figure 4 Measurement field of the infrared camera optris PI representing the 23 x 17 lens...
Страница 28: ...28 Figure 7 PI400 PI450 PI450G7 PI640 PI1M dimensions mm...
Страница 31: ...31 Mechanical Installation Figure 10 Cooling Jacket Dimensions...
Страница 32: ...32 Figure 11 Cooling jacket for PI Part No ACPIxxxCJ Figure 12 Cooling jacket with mounting bracket...
Страница 36: ...36 Figure 14 Cooling Jacket Advanced Part No ACPIxxxCJAE Extended Version 38 62 optics Dimensions...
Страница 48: ...48 Figure 24 Stand Alone operation with PI Netbox Figure 25 USB Server Gigabit...
Страница 52: ...52 5 2 Software window Figure 27 Software window...
Страница 61: ...61 Basics of Infrared Thermometry Figure 31 Non contact thermometry...
Страница 68: ...68...
Страница 69: ...69 Emissivity metals Appendix A Table of emissivity for metals...
Страница 70: ...70...
Страница 71: ...71 Emissivity non metals Appendix B Table of emissivity for non metals...
Страница 72: ...72...
Страница 74: ...74 Command list The command list is provided on the software CD Every command must expire with CR LF 0x0D 0x0A...
Страница 76: ...76...
Страница 78: ...78...
Страница 82: ...82 Figure 41 Relay output at industrial PIF...
Страница 83: ...83 CE Conformity Appendix G CE Conformity...
Страница 84: ...84...
Страница 85: ...optris PI MA E2014 12 A...