H79
4-1
Chapter 4
Function Test & Alignment Procedure
4-1
Product
-
H79
4-2
Test Equipment
-
IBM PC with XGA resolution (Color Video Signal & Pattern Generator)
-
DVD player with component video (Y, Pb, Pr) and Multi-system (NTSC / PAL / SECAM)
-
HDTV Tuner or Source (480i/p, 576i/p, 720p, 1080i)
-
Minolta- CL-100
-
Chroma 2723
4-3
Test Condition
-
Circumstance Brightness
1.)Dark room less than 10 lux for functional inspection.
2.)Circumstance brightness over than 500 lux for external inspection.
-
Inspection Distance
1.)About 2.25m for functional inspection (The projection distance has to base on the
screen size till 60 inches)
2.)30cm for external inspection.
-
Screen Size : 60 inches diagonal (wide)
-
Each H79 should be run-in for 2 hours after repair.
1.)In room temperature
2.)With cycled display colors (R,G,B,White)
*Note
-
Run-in Time: (CT-FL-03002)
After changing all materials:
1.)For DC-DC and Ballast, it will run-in 2 hours.
2.)For DMD BD, Main BD,Thermal BD and Engine,it will run-in 4 hours.
3.)No Fault Fault (NFF)
: it will run-in 4 hours.
4.)Auto Shutdown: it will run-in 6 hours.
*Note : Please enter Service Mode to select run-in function. (For cycled display color mode)
The procedure for entering Service Mode: Press RESYNC, SOURCE, ENTER button
at same time.
Содержание H79
Страница 16: ...H79 2 8 3 Unscrew 8 screws to remove Ballast Module and Engine Module BallastModule EngineModule ...
Страница 20: ...H79 2 12 7 Unscrew one screw to remove Thermal Switch ThermalSwitch ...
Страница 42: ...H79 6 3 6 3 EDID Upgrade Procedure 1 Execute EDID program 2 Press Mode button ...
Страница 46: ...H79 6 7 9 Themessagesof OK andthe DigitalValues will show ...
Страница 47: ...H79 7 1 Appendix A Exploded Overview ...