EW610ST/EX610ST/EW605ST/EX605ST
Confidential
4-1
Chapter 4
Function Test & Alignment Procedure
4-1 Service Mode Instruction
(This section
links to common service manual 4-2 Service
Mode)
1. Turn on the projector.
2.
Press Power --> Left --> Left --> Menu on Keypad or Remote
controller.
3. Service mode will be shown. After confirming the configuration,
press "Exit" to exit.
4-2 Factory Fan RPM Reset
After replace main board,blower or upgrade system FW, you need to
do:
1. Plug in the power cord, power on the projector, when the“logo”
disappear, to press “Power”, “Left”, “Left” and “right” button in
sequence, then Picture A will be shown.
2. After several minutes, you can check the fan RPM as red circle
a. Please get into Service Mode.
b. Select “Fan menu”, then press “Enter”, Fan detail information
will be shown.
Note: If the factory fan Value don’t show in service mode,please
repeat the step 1,2 again.