3-3 Main Procedure
The other troubleshooting procedures please refer to common service manual
3-1(Main Procedure).
No
Symptom
Procedure
1
Auto Shut Down
- Ensure the projector is not put on a soft pad and the air vent is not
blocked.
- a. Lamp Fail: Power LED (flashes amber), Lamp LED (lights red)
- Check Lamp
- Check Lamp Driver
- Check Main Board
b. Over Temp: Power LED (flashes amber), Temp LED (lights red)
- Check Fan
- Check Main Board
- Check thermal switch
c. Fan Fail: Power LED (flashes amber), Temp LED (flashes red)
- Check Fan
- Check Main Board
3D Image Abnor
-
mal
- Ensure the using 3D glasses is good and you must face the
projection.
- Ensure the CD in DVD is HQFS format or the graphic card from
PC can support 3D format.
- Ensure your standing distance is less than 6m from screen.
- Ensure the 3D function is on and execute “3D sync invert” in OSD
menu.
- Check main board.